Control Board Test Points - Whirlpool 6ADP2956 IXM Service Manual

Table of Contents

Advertisement

WHIRLPOOL CONSUMER SERVICES

CONTROL BOARD TEST POINTS

A pair of long, wire claw type probes are required to access the test points.
Checking voltages at the test points will determine the correct operation of the function push
buttons and the rotary switch.
Before attaching test probes to the control board test points which are accessed via the control
board service window, disconnect the dishwasher from the supply. Short circuiting of any of the
electronic components will cause the control board to fail.
Test Points : T0 = Common
T1 = Analogue voltage
A voltmeter with a high input impedance is required to measure the control board voltages.
The degree of agreement between the measured voltage and the nominated voltage will be
dependent on the accuracy of the voltmeter.
Test Point T0 to T1
Communication between control board and display board
Operated Push Button
All off
ZW (1 or both LED's)
Delay
ZW and Delay
Test Point T0 to T2
Communication between control board and user board
Rotary Switch
O
Cycle 1
Cycle 2
Cycle 3
Cycle 4
Cycle 5
Cycle 6
Test Point T0 to T3
Communication between control board and display board
Start button out (LED off)
Start button in (LED on)
Service Window
T0
T3
T2
Control Board
Voltage (V dc)
-5.24
-3.43
-2.88
-2.88
Voltage (V dc)
0.00
-1.32
-1.75
-2.20
-2.90
-3.36
-3.80
-5.24 V dc
-3.87 V dc
Model 6ADP2956 IXM
T2 = Analogue voltage
T3 = Digital signal
T1
Page 19 of 19