WHIRLPOOL CONSUMER SERVICES Model 6ADP2956 IXM Page 3 of 19 CONTENTS Page TECHNICAL DATA 4 - 5 EXPLODED VIEW - CABINET EXPLODED VIEW - DOOR AND CONTROL PANEL SPARE PARTS LIST 8 - 11 PROGRAMME CHART CIRCUIT DIAGRAM TEST PROGRAMME...
WHIRLPOOL CONSUMER SERVICES Model 6ADP2956 IXM Page 4 of 19 TECHNICAL DATA Dimensions Electrical Data Height 85.0 Base Data Width 60.0 Voltage 230 - 240 Depth 59.2 Frequency Mass 59.0 Total power Fuse Decor Plate Motors Thickness (Max) Width Spray Pump Motor...
WHIRLPOOL CONSUMER SERVICES Model 6ADP2956 IXM Page 5 of 19 TECHNICAL DATA (Cont.) Heating Water Quantities and Levels Voltage 230 - 240 V Power consumption 2.22 Measuring Water Level Resistance • Heating rate ºC/min Remove the coarse sieve, place end of a ruler Temperature on surface ~115 ºC...
WHIRLPOOL CONSUMER SERVICES Model 6ADP2956 IXM Page 14 of 19 TEST PROGRAMME To start the passive test programme : 1. Turn the programme selector to OFF 2. Hold the start button in and at the same time turn the programme selector to the first cycle (40°C-55°C Normal).
WHIRLPOOL CONSUMER SERVICES Model 6ADP2956 IXM Page 15 of 19 After completion of any repair, run the test programme again to confirm repairs have been effective. NOTE 1 : The first step with test programme of new service control boards is without any backrinsing steps.
WHIRLPOOL CONSUMER SERVICES Model 6ADP2956 IXM Page 16 of 19 FAULT DIAGNOSIS Sensor Failure There is no indication to the user for this fault. If the sensor fails, the machine will automatically default to the programme with the highest washability.
Page 17
WHIRLPOOL CONSUMER SERVICES Model 6ADP2956 IXM Page 17 of 19 Water Control Cock Closed (Only indicated at the start of the active test) Water valve (WV1) is energised but flow meter (FM) sends no impulses to CPU (less than 10 impulses in 10 seconds) and the water indicator is at low level.
WHIRLPOOL CONSUMER SERVICES Model 6ADP2956 IXM Page 18 of 19 ACTIVE TEST PROGRAMME Start the active test procedure by first running the passive test then press the start button for less than three seconds. Notes : Operation Function When the machine detects a fault during...
WHIRLPOOL CONSUMER SERVICES Model 6ADP2956 IXM Page 19 of 19 CONTROL BOARD TEST POINTS A pair of long, wire claw type probes are required to access the test points. Checking voltages at the test points will determine the correct operation of the function push buttons and the rotary switch.