NEC Versa 2400 Series Service Manual page 95

Notebook computer
Hide thumbs Also See for Versa 2400 Series:
Table of Contents

Advertisement

Problem
PCMCIA card does not work
Trackball doesn't work
Serial device does not work
Parallel device does not work
Table 5-5 Quick Troubleshooting
Corrective Actions
Check the PCMCIA driver installation for any
IRQ or IO address conflict.
Check if the PCMCIA card is inserted properly
and all connections are set.
Replace the PCMCIA card.
Replace the system board.
Check if trackball is enabled under CMOS Setup.
Check if PS/2 mouse driver is properly installed.
Check trackball cable inside the system if it is
inserted properly.
Remove trackball ring cover and clean the ball
and the rollers inside.
Replace trackball module.
Check the keyboard controller chip for any cold
or loosed soldering.
Replace the system board.
If using serial mouse, check if trackball option is
disabled under CMOS Setup.
Check if mouse driver is installed properly.
Check if serial device is connected properly.
Replace serial device.
Check the I/O controller chip on the system
board for any cold or loosed soldering.
Replace the system board.
Check if all connections are properly set.
Check if external device is turned on.
Check I/O controller chip on the system board for
any cold or loosed soldering.
Replace the system board.
Troubleshooting and Repair
5-11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Versa 240xVersa 240xcdVersa 243xcd

Table of Contents