Transmission Data Format; Transmission Data Format From Host To Slave; Form1: Command; Form2: Status Request - Marantz SR5400 Specification

Rs-232c control specification
Hide thumbs Also See for SR5400:
Table of Contents

Advertisement

SW-A0441-HSI-002

3-2. Transmission data format

3-2-1. Transmission data format from Host to Slave

There are two kinds of transmission data form from Host shown below.

3-2-1-1. Form1: Command

Command is a data that requests some status change.
Start character
ID
COMMAND
End character
S tart
'@ '

3-2-1-2. Form2: Status request

Status request is a data that requests a answer of some status.
Start character
ID
Request character : '?'
Request status
End character
S ta rt
'@ '

3-2-2. Transmission data format from Slave to Host

There are two kinds of transmission data form from Slave shown below.

3-2-2-1. Form1: ACK/NAK

ACK is a reply data from Slave when Slave got an acceptable command data from Host.
ACK
A C K
0 6 h
NAK is a reply data from Slave when Slave got an incorrect Command data, Status request data or
some other data from Host.
NAK
N A K
1 5 h

3-2-2-2. Form2: Status answer

Status answers are reply data when Slave got an acceptable Request status data from Host.
Start character
ID
Answer character
End character
All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of copyright.
Hardware Software Interface (HSI)
: '@'
: '0' ~ '9' (A Slave has own ID, A Host has to set the ID.)
: see "Command list"
: 0Dh
C O M M A N D
ID
: '@'
: '0' ~ '9' (A Slave has own ID, A Host has to set the ID.)
: see "Status request list"
: 0Dh
R e q u e s t s ta tu s
ID
'?'
: 06h
: 15h
: '@'
: '0' ~ '9' (A Slave will set own ID.)
: see "Status answer list"
: 0Dh
Marantz America, Inc. 2007
All specifications might be subject to change without notice.
Document Version [1.00b]
E n d
0 D h
E n d
0 D h
Page: 5 / 17