Operation
Comfortable SLEEP
Operation
Before going to bed, you can simply press the
SLEEP button and unit will operate in SLEEP
mode and bring you a sound sleep.
Use of SLEEP function
After the unit starts, set the operation status,
then press SLEEP button before which the
clock must be adjusted and time being set.
HEALTH
ON/OFF
MODE
SWING
TIMER
CLOCK
SET
LOCK

Operation Mode

1. In COOL,DRY mode
1 hours after SLEEP mode starts, temp. will
become 1
C higher than temp. setting. After
O
another 1 hours, temp. rises by 1
The unit will run for further 6 hours then stops.
Temp. is higher than temp. setting so that room
temperature won't be too Iow for your sleep.
SLEEP operation starts
Approx.6hrs
Rises 1
1 hr
O
Rises 1
C
1 hr
Temp.setting
In COOL, DRY mode
2. In HEAT mode
1 hours after SLEEP mode starts, temp will
become 2
C lower than temp.setting. After
O
another 1 hours, temp decrease by 2 C
further. After more another 3 hours, temp.
O
rises by 1 C further. The unit will run for
FAN
SLEEP
RESET
C further.
O
SLEEP operation stops
O
C
Unit stop
O
further 3 hours then stops. Temp. is lower
than temp. setting so that room temperature
won't be too high for your sleep.
Temp.setting
1 hr
Decreases 2
O
1 hr
Decreases 2
3 hrs
SLEEP
operation starts
In HEAT mode
3. In AUTO mode
The unit operates in corresponding sleep
mode adapted to the automatically selected
operation mode.
4. In FAN mode
It has no SLEEP function.
5.
When TIMER function is set, the sleeping function
can't be set up .After the sleeping function is set up
if user resets TIMER function, the sleeping function
will be cancelled; the machine will be in the state of
timing-on.
6.Note to the power failure resume:
press the sleep button ten times in five seconds
and enter this function after hearing four sounds.
And press the sleep button ten times within five
seconds and leave this function after hearing
two sounds.
Power Failure Resume Function
If the unit is started for the first time, the
compressor will not start running unless 3
minutes have elapsed. When the power
resumes after power failure, the unit will run
automatically, and 3 minutes later the
compressor starts running.
15
Unit stop
C
C
O
3 hrs
Rises 1
O
C
SLEEP
operation stops