GE APE08AK - Portable Room Air Conditioner Owner's Manual And Installation Instructions page 5

Portable room air conditioner
Table of Contents

Advertisement

g_com
When the air conditioner is turned on, # will
automatically start in the default setting.
Remote Control
::Ji:: T o ensure
proper
operation,
aim
the
remote
control
at the
signal
receiver
on
the air conditioner.
::Ji:: T he
remote
control
signal
has a range
of up to
21 tibet.
::Ji:: Make
sm'e
nothing
is between
the
air conditioner
and
the
remote
control
that
could
block
the
signal.
::Ji:: Make
sm'e
batteries
are
fl'esh
and
installed
correctl}_see
the Using
the portable air conditioner
section.
FAN Mode
Use the FAN at HIGH,MID or LOW to provide
air
drculation
and filtering
without
cooling,
Since tim
Olfly settings
do not provide
cooling,
a temi)eramre
setting will not be displayed.
COOLMode
Use the COOL mode with HIGH,MID or LOWfim
fin" cooling. Use the TempINCREASEA/DECREASEV
pads to set the desired
temperatm'e
between
61°F
and 86°F in 1 °F increments.
A them_ostat
is used
to maintain
the
room
temperature.
The
compressor
will cycle on and
off
to kee I) the
room
at the
set level
of comtort.
Set the
them_ostat
at a lower
numl)er
and
the
indoor
air
will become
coole_;
Set the
them_ostat
at a higher
number
and
the
indoor
air will become
wam_e_;
NOTE:ffthe air conditioner is off and is then turned on
while set to a Coolsetting or if turned from a fan setting
to a Cool setting, # will take approximately3 minutes for
the compressor to start and cooling to begin.
Cooling Descriptions
For Normal
Cooling--Select
the
COOL mode
and
HIGH or MIDtim
Mth
a middle
set temperature.
For Maximum
Cooling--Select
the
COOL mode
and
HIGHIan
with
a lower
set temperature.
ForQuieter& Nighttime
Cooling--Select
the
COOL
mode
and
LOWflm
with
a middle
set temperatm'e.
NOTE:If you switch from a COOL setting to OFFor to
a fan setting, war at least 3 minutesbefore switching
back to a COOL setting.
DRY Mode
Use the
DRYmode
to provide
dehumidification
only: The
tim will run
at a low fixed
speed
at this
setting.
Kee I) windows
and
do(n_
closed
fi)r the
best
dehumidit)'ing
effects.
When
using
the
ORYmode,
detach
the
exhaust
hose
fl'om
the
refit and
remove
the window
slider
or seal the
opening
in the
window
exhaust
adapte_;
NOTES:
If you sMtch fl'om a DRYsetting
to OFF or to a tim
setting,
wait at least 3 minutes
beflwe switching
back
to a DRYsetting.
The compressor
runs in this mode.
AUTO Mode
Set to
AUTO
for the
temperature
and
tim speed
to
automatically
provide
optimum
comfi)rt
settings.
NOTE: DRYwill also appear in the display when using
theAUTOmode.