Window Mounting

Remove Chassis

1
1. Pull down front panel and remove filter. (See FIG. 1).
2. Lift front upwards and place to one side.
FIG. 1
3. Locate the four front screws and remove. These screws will
be needed to re-install the front later. (See FIG.2)
4. Pry away front from cabinet sides as per photo (see FIG.3)
5. Gently lift front off unit and place to one side (See FIG.4).
FIG. 3
6. Remove shipping crews from top of unit and also on the side
by the base if installed.
7. Hold the cabinet while pulling on the base handle, and care-
fully remove the unit.
8. Add two foam inserts to holes in top of cabinet where
shipping screws were removed from.
9. Your unit may come with internal packaging.THIS
PACKAGING MUST BE REMOVED PRIOR TO
INSTALLING THE AIR CONDITIONER BACK
INTO THE CABINET. (See FIG. 5).
Internal Packaging
FIG. 2
FIG. 4
.
FIG. 5
Install Top Angle
2
and Side Bracket
1. Attach foam gasket to top angle above holes as
shown in FIG. 6.
2. Install top
angle and
side retainers
to cabinet as
shown in FIG. 6.
Assemble Window
Filler Panels
3
1. Place cabinet on floor, a bench, or a table.
2. Slide "I" section of window filler panel into side retainer
on the side of the cabinet (see Figures 7-8). Do both
sides.
FIG. 7
PLASTIC
FRAME
FIG. 8
TOP
VIEW
3
FIG. 6
WINDOW FILLER
PANEL
SIDE
RETAINER
AIR CONDITIONER
PLASTIC
CABINET
FRAME
LOCKING
SCREW
"I" SECTION
WINDOW
HOLE
FILLER
PANEL

Hide quick links: