Download Print this page

Ordering Information - Omron J7KN Datasheet

Motor contactor

Advertisement

Ordering Information

■ Model Number Legend
1. Motor Contactors
J7KN#-###-##-####
1
2
3
4
5
1)
Motor Contactor
2)
G: DC solenoid motor contactor
3)
Rated Motor Current (AC3 400V)
10:
10A
14:
14A
18:
18A
22:
22A
24:
24A
32:
32A
40:
40A
50:
50A
62:
62A
74:
74A
85:
85A
110: 110A
151: 150A
176: 175A
200: 200A
4)
Integrated auxiliary contact
10: 1NO 0NC
01: 0NO 1NC
21: 2NO 1NC
22: 2NO 2NC
: 0NO 0NC
4: 4 main poles
5)
Coil voltage (AC operated)
24: AC24V 50/60Hz
48: AC48V 50Hz
90: AC100V 50/60 Hz
110: AC110V 50Hz, AC110-120V 60Hz
180: AC180-210V 50Hz, AC200-240V 60Hz
230: AC220-240V 50Hz, AC240V 60Hz
400: AC380-415V 50Hz, AC415-440V 60Hz
500: AC500-550V 50Hz, AC550-600V 60Hz
Coil voltage(DC operated)
24D: DC24V
48D: DC48V
110D: DC110V
125D: DC125V
Coil voltage(DC solenoid operated - G-type)
24D: DC24V
48D: DC48V
60D: DC60V
110D: DC110V
125D: DC125V
220D: DC220V
Coil voltage(AC & DC operated) for J7KN 151 & J7KN 176 only
24: 24V 50/60Hz, 24VDC
48: 48V 50/60Hz, 48VDC
110: 110-120V 50/60Hz, 110VDC
230: 220-240V 50/60Hz, 220VDC
400: 380-415V 50/60Hz
26
Motor Contactor
J7KN
2. Sytem Contactors for Fuseless Load Feeders with integrated
Link Module
J7KN-###-##-###-VK3
1
2
3
4
5
1)
Additional reference for LVSG
2)
Rated Motor Current (AC 3 400 V)
10: 10 A
14: 14 A
18: 18 A
22: 22 A
3)
Integrated Auxiliary Contact
10: 1NO 0NC
01: 0NO 1NC
4)
Coil voltage (AC operated)
24: AC24V 50/60Hz
48: AC48V 50Hz
110: AC110V 50Hz, AC110-120V 60Hz
180: AC180-210V 50Hz, AC200-240V 60Hz
230: AC220-240V 50Hz, AC240V 60Hz
400: AC380-415V 50Hz, AC415-440V 60Hz
500: AC500-550V 50Hz, AC550-600V 60Hz
5)
Attached link module VK 3
3. Aux. Contact Modules for Motor Contactors
J73KN-#-##-#
1
2 3 4
1)
Auxiliary Contact Modules
2)
B: for motor contactor (4-37kW)
C: for motor contactor (11-37kW)
D: for motor contactor (75-90kW)
E: for motor contactor (110kW)
3)
Combination of NO/NC contacts
10: 1NO 0NC
01: 0NO 1NC
11: 1NO 1NC
22: 2NO 2NC
4)
S: side mounting for motor contactor (11-37kW and
75-90 kW)
: front mounting for motor contactor (4-37kW)
A: 6A version
F: front mounting for motor contactor (75-90kW)
U: EM and LB version
4. Accessories for Motor Contactors
(Pneumatic Timers)
J74KN-#-## ### ##
1
2 3
4
5
1)
Accessories for Motor Contactors
2)
B: Motor Contactor (4-18.5kW)
3)
TP: Pneumatic Timer
4)
40: 40 sec
180: 180 sec
5)
DA: ON-delayed
IA: OFF-delayed
5. Accessories for Motor Contactors (Mechanical Interlock)
J74KN-#-##
1
2 3
1)
Accessories for Motor Contactors
2)
B: Motor Contactor (4-18.5kW)
C: Motor Contactor (11-37kW)
D: Motor Contactor (45-55kW)
E: Motor Contactor (75-90kW)
3)
ML: Mechanical Interlock

Advertisement