ITEM
Resistance to
Vibration (to IEC 68-2-6)
Shock (to IEC 68-2-27)
Rated operating voltage
Operating voltage range
Current consumption
Power-on delay
Outputs
Output circuit protection
Output current
Max. Capacitive load
Output voltage drop
Residual current
Circuit protection
Input circuit
Input pulse duration
Response time
Reset time (TOFF 'TON) (interlock)
Insulation resistance
Dielectric voltage strength
Configuration
Operating modes
30
VALUE
10 - 70 Hz 1.5mm amplitude, X, Y, Z directions
30G, 16ms, X, Y, Z direction
+ 24 V DC, polarized
+19.2 ... 28.8 VDC
< 420mA (muting lamp included)
< 800ms
PNP
PNP short circuit protected
250 mA each OSSD
200nF (pure capacitive load)
< 2.0 V
(excl. voltage drop due to cable extension)
< 100 µA
Reverse polarity,
Overload
Short-circuit (pulsed)
Logical Zero level 0 - 8 V
Logical One level 14 - 24 VDC
Min. 2 cycle time
16ms
300ms
800 M @ 500 VDC
350 VAC, 50/60 Hz (1 min)
Manual reset / Automatic reset (default)
Muting / Override (by wiring setting)