Operation - Omron E3X-NL Datasheet

Optical fiber glossy object sensor
Table of Contents

Advertisement

Operation

Sensitivity setting
Two-point teaching
Pro
ce-
Setting
dur
e
Locate the sensor head within the sensing
1
---
distance.
TEACH
Move the mode selector to the
2
RUN
ON
position.
TIMER
OFF
Press the teaching button once with a
sensing object located under the sensor
as shown in the following illustration.
TEACH
3
Teaching indicator ... Lit red
The built-in buzzer beeps once.
With an object absent (ground), press the
TEACHING button (second time).
TEACH
If teaching is OK
4
Teaching indicator ... Lit red
The built-in buzzer beeps once.
If teaching is NG
Teaching indicator ... Lit red
red
The built-in buzzer beeps 3 times.
Change the object position and setting
distance again and make setting in order of
1 to 4.
Move the mode selector to the
sition. Sensitivity setting is complete.
TEACH
5
RUN
ON
Teaching indicator ... Lit green
TIMER
OFF
guished
Light Dark
Select the desired operation
L.ON
6
format with the operation mode selector
D.ON
(L.ON/D.ON).
E3X-NL
Operation
TEACH
Object
Base
Object
Base
Lit green
Flickers
RUN
po-
Extin-
One-point teaching
Pro
ce-
Setting
dur
e
TEACH
Move the mode selector to the
1
RUN
ON
position.
TIMER
OFF
Press the teaching button with one of the
sensing objects or the background object
located under the sensor for sensing.
2
Teaching indicator ... Lit red
The built-in buzzer beeps once.
Move the mode selector to the
sition. 1-point teaching setting is complete
TEACH
as soon as the first object passes.
3
RUN
ON
TIMER
OFF
Teaching indicator ... Lit red
green
Select the desired operation format with
L.ON
4
the operation mode selector (L.ON/D.ON).
D.ON
Operation
TEACH
RUN
po-
Lit
A-203

Advertisement

Table of Contents
loading

Table of Contents