14. ERROR CODES

If you use a wireless remote controller, the lamp on the photo detector unit will output error
codes by way of blinking patterns. If you use a wired remote controller, error codes will ap-
pear on the remote control display. See the lamp blinking patterns and error codes in the
table. An error display is displayed only during operation.
The error code table contains errors irrelevant to this product as well.
Error display
OPERATION
TIMER
ECONOMY
lamp
lamp
lamp
(green)
(orange)
(green)
(1)
(1)
(1)
(2)
(1)
(5)
(1)
(6)
(1)
(8)
(2)
(1)
(2)
(2)
(2)
(3)
(2)
(4)
(2)
(6)
(2)
(7)
(2)
(9)
(3)
(1)
(3)
(2)
(3)
(3)
(3)
(5)
(3)
(9)
(3)
(10)
(4)
(1)
(4)
(2)
(4)
(4)
(5)
(1)
(5)
(3)
(5)
(4)
(5)
(5)
(5)
(7)
En-10
Error code
Description
Serial communication error
• Wired remote controller
communication error
• Server room control
communication error
Check run unfinished
Automatic airflow adjustment error
Peripheral unit transmission PCB
connection error
External communication error
Unit number or Refrigerant circuit
address setting error
[Simultaneous multi-split type]
Indoor unit capacity error
Combination error
• Connection unit number
error (indoor secondary unit)
[Simultaneous multi-split type]
• Connection unit number error
(indoor unit or branch unit)
[Flexible multi-split type]
Indoor unit address setting error
Primary unit, secondary unit setup
error [Simultaneous multi-split type]
Connection unit number error in
wired remote controller system
Power supply interruption error
Indoor unit PCB model
information error
Indoor unit motor electricity
consumption detection error
Manual auto switch error
Indoor unit power supply error for
fan motor
Indoor unit communication circuit
(wired remote controller) error
Room temp. sensor error
Indoor unit heat ex. middle temp.
sensor error
Human sensor error
Indoor unit fan motor error
Drain pump error
Electric air cleaner reverse VDD
error
Filter set error
Damper error
Error display
OPERATION
TIMER
ECONOMY
lamp
lamp
lamp
(green)
(orange)
(green)
(5)
(8)
(5)
(9)
(5)
(10)
(5)
(15)
(6)
(1)
(6)
(2)
(6)
(3)
(6)
(4)
(6)
(5)
(6)
(8)
(6)
(10)
(7)
(1)
(7)
(2)
(7)
(3)
(7)
(4)
(7)
(5)
(7)
(6)
(7)
(7)
(8)
(2)
(8)
(3)
(8)
(4)
(8)
(6)
(9)
(4)
(9)
(5)
(9)
(7)
(9)
(8)
(9)
(9)
(9)
(10)
(10)
(1)
(10)
(3)
Error code
Description
Intake grille error
Indoor unit fan motor 2 error
(Left side fan)
Indoor unit fan motor 3 error
(Right side fan)
Indoor unit error
Outdoor unit reverse/missing
phase and wiring error
Outdoor unit main PCB
model information error or
communication error
Inverter error
Active filter error, PFC circuit error
Trip terminal L error
Outdoor unit rush current limiting
resister temp. rise error
Display PCB microcomputers
communication error
Discharge temp. sensor error
Compressor temp. sensor error
Outdoor unit Heat Ex. liquid temp.
sensor error
Outdoor temp. sensor error
Suction Gas temp. sensor error
• 2-way valve temp. sensor error
• 3-way valve temp. sensor error
Heat sink temp. sensor error
• Sub-cool Heat Ex. gas inlet
temp. sensor error
• Sub-cool Heat Ex. gas outlet
temp. sensor error
Liquid pipe temp. sensor error
Current sensor error
• Discharge pressure sensor error
• Suction pressure sensor error
• High pressure switch error
Trip detection
Compressor rotor position
detection error (permanent stop)
Outdoor unit fan motor 1 error
Outdoor unit fan motor 2 error
4-way valve error
Coil (expansion valve) error
Discharge temp. error
Compressor temp. error