Operation; Control Panel Overview; Overview Of Keys - Bosch Condens GC4700iW 15 S User Instructions

Gas-fired condensing appliance
Table of Contents

Advertisement

▶ Remove the hose [2] and replace the blanking cap [1].
1
7
8
Fault - 1017
System pressure ok.
System pressure
Stop refilling
Pressure OK: 1.5 bar
Pressure: 0.6 bar
Fig. 5
External filling loop
If the pressure gauge reads more than 1.7 bar as a result of over filling:
▶ Bleed one radiator until the pressure gauge returns to between 1 and
1.7 bar.
▶ It is good practice to bleed any excess air that has entered the heating
system due to pressure loss. Locate and open the radiator's bleed/
vent point, closing the valve when water begins to flow.
▶ If, through normal boiler operation, the PRV pipe starts to leak, it
could be a sign of system pressure being too high. In this instance
please bleed a radiator as described above.
Semi-sealed heating system
Appliances that can be connected to semi-sealed heating systems will
have the pressure maintained automatically by the header tank feeding
the system.
4

Operation

These operating instructions describe the operation of the gas-fired
condensing boiler. Therefore please also observe the operating
instructions for the user interface.
Condens 4700iW – 6721864485 (2023/04)
3
2
5
4
6
too low
0010033763-001
4.1

Control panel overview

1
8
7
6
5
Fig. 6
Overview
[1]
Burner display: Illuminates when the burner is alight.
[2]
Display.
 and  buttons: To navigate through menus and increase/
[3]
decrease settings.
[4]
d button: Return/back.
1)
[5]
ok button
: Selection/save settings.
[6]
Menu button.
[7]
Hot water button: Hot water mode on/off, adjusting the hot water
temperature.
[8]
Heating button: Heating mode on/off, set the maximum flow
temperature.
4.2

Overview of keys

Key
Function
(
Heating
• Heating mode
*
Domestic Hot Water (DHW)
• DHW mode
Menu
• Access to menus
1)
ok
Select/save
• Confirm a selection
• Save setting
• DHW eco/preheat
"
Back arrow
• Exit menu (without saving changes)
.
Up arrow
• Menu navigation
• Increase values
/
Down arrow
• Menu navigation
• Reduce values
1) When the display is in power save mode the ok button will re-activate the screen
Table 4 Overview of keys
1) When the display is in power save mode the ok button will re-activate the screen
Operation
2
3
4
0010031533-001
7

Advertisement

Table of Contents
loading