VENT TERMINATION CLEARANCES
CLEARANCE
Clearance below or beside any door or window
4 feet
that opens.
Clearance above any door or window that
1 foot
opens.
3 feet
Clearance from any adjacent building.
Clearance from any grade when adjacent to
7 feet
public walkways.
Clearance above any grass, plants, or other
2 feet
combustible materials.
Clearance from any forced air intake of any
3 feet
appliance.
2 feet
Clearance below eaves or overhang.
Clearance horizontally from combustible
1 foot
wall.
3 feet
Clearance above the roof.
Clearance above the highest point on the roof
2 feet
within 10 feet.
VENTING INSTALLATION EXAMPLES
FLOOR PROTECTION
STRAIGHT INSTALLATION
Outside Vertical Rise, Through Wall Installation
800-345-6007
CumberlandStoveWorks.com
INSTALLATION AND OPERATION MANUAL
MF3500G, MF3500S, MF3500B Models
FLOOR PROTECTION
STRAIGHT INSTALLATION
Inside Vertical Rise, Horizontal Termination
Page 5