What To Do If An Error Occurs - Panasonic GT707 Series User Manual

Programmable display
Hide thumbs Also See for GT707 Series:
Table of Contents

Advertisement

4.1 What to Do If an Error Occurs

Problem
Cause
Power is not on.
The power voltage may be low.
When only lamp and message
parts are configured to the base
screen, the value of substitute
Screen is blank.
reference device value does not
exist in substitute data.
The backlight is off due to the
[Backlight Control (Auto-Off)]
setting in the [Setup] of the GT
configuration settings in GTWIN.
An error has occurred in
Error code [ER****]
communication between the GT
appears at the top
and an external device (e.g.
right of the screen.
PLC).
Screen displays [No
There is no screen data in the
Screen data].
GT.
Screen settings from the PLC, the
GT's switch part or the auto-
paging indicate an unregistered
screen number.
When bringing up the keyboard
Screen displays
screen during data input, an
[Screen No. Error].
unregistered keyboard screen
number was specified.
GT configuration data and
keyboard screen data exist in the
GT, but there is no base screen
data.
The total capacity of transferred
Screen displays
base screen data exceeds the
[Memory is Full]
memory capacity of the GT.
The screen specification in the
PLC screen setting, the GT switch
part or the auto-paging is wrong.
An unspecified
The startup screen is specified in
screen
the GT configuration settings
appeared/there is
(GTWIN).
trouble when
switching screens.
An erroneous device or value is
specified in the first word of the
basic communication area word
device.
Ramco Innovations
Solution
Check the power within the specifications is
supplied.
Check the capacity of the power supply unit if it is
enough for the GT's power consumption.
Check the address of the substitute reference
device and the device values on the PLC side.
Touching any area of the screen lights that area.
If a switch part is set on the touched area, the
area will not light even if touched. To change the
setting, change the setting of "Backlight Control
(Auto-Off)".
Refer to <4.2 Error Codes and How to Handle
Them>.
Select "Communication" in the GTWIN menu and
transfer screen data.
Create and register screen content or specify the
correct screen number.
Create and register a keyboard screen or specify
the correct keyboard screen number.
Transfer base screen data from GTWIN.
Delete part of the base screen data so that the
capacity doesn't exceed the total capacity. Data
capacity can be checked by going to [View (V)] >
[Total Memory Usage] on GTWIN menu bar.
When the data capacity is not over the limit,
invalid data could possibly be remaining in the
GT. When transferring data, do so after deleting
the screen.
Specify a correct screen number.
Check the start-up screen setting for the GT
configuration settings in GTWIN. Delete
unnecessary settings and re-transfer
configuration data.
Check the device content specified on the PLC
side in the first word of the basic communication
area. Make a program not to overwrite the basic
communication area by other applications.
www.panasonicsensors.com
(800) 280-6933

Advertisement

Table of Contents
loading