Culligan Aqua-Cleer Owner's Manual page 14

Drinking water system
Table of Contents

Advertisement

12
Servicing Your System (cont'd)
6. In this step, you will need to observe water flowing to the drain. If the drain flow is not
visible with the current tubing connections, install a temporary drain tube in the waste
port of the manifold. Turn on the supply valve. When water is seen flowing to the
drain, carefully loosen the capillary tube assembly retaining screws until the flow to
the drain increases.
NOTICE: When the assembly is about 3/16" out of the manifold, the o-ring seal for the capil-
lary tube is bypassed, but there should be no external leaks.
7. Rinse the manifold assembly for five minutes or until no chlorine is detected in the
water passing to the drain. Tighten the capillary assembly retaining screws.
8. Check the performance of the system according to the procedure outlined in the
"Performance and Technical Information" section of this manual. Replace the RO
membrane if necessary.
9. Instruct the customer to discard the first glassful of water from the system to flush
out any residual chlorine that might remain in the polishing filter tubing and faucet.
The polishing filter will remove any chlorine remaining in the storage tank.
10.Record your service on the chart at the end of the Owner's Guide.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aqua-cleer good water machine

Table of Contents