I P T E S T PA R A M E T E R S
Following any repair or maintenance procedure that requires disassembly of the fixture, use Elation's
IP Tester to confirm the IP integrity of the fixture. Please contact Elation Service for information
regarding the Elation IP Tester, or visit the product information page online at:
elationlighting.com/ip-tester
CAUTION! THE USE OF PROTECTIVE GLOVES AND SAFETY GOGGLES IS STRONGLY
RECOMMENDED WHILE PERFORMING THE IP PRESSURE TEST! AVOID PLACING YOUR
FACE, EYES, HANDS, ETC IN PROXIMITY TO THE LENS OF THE FIXTURE WHILE
PERFORMING THE TEST!
DE-HUMIDIFICATION: IP66 fixtures operating in high-humidity environments may experience residual
fogging or condensation. Such fogging will not affect the fixture, and can be removed using the following
procedure: position the unit with the air valve pointing upwards, then open the air valve and run the
unit for 1-2 hours after reaching operating temperature. Then, while the fixture is still hot, re-install
the air valve and allow the unit to cool down. Please note: this procedure should be performed in a
dry, climate-controlled environment. Avoid additional fogging by drying the fixture completely before
placing into a road case.
Carefully remove Lens
Collar and Rear Cover
Plate as shown.
Test Type
Vacuum Test
Pressure Test
IP PRESSURE TESTING PARAMETERS
Low Pressure Limit
-4.35psi (-30.00 KPa)
3.62psi (25.00 KPa)
High Pressure Limit
-5.08psi (-35.00 KPa)
4.35psi (30.00 KPa)
16
https://www.
Valves
Hold Time
10s
10s