Paradyne 7975 Installation Instructions Manual page 9

M/sdsl standalone termination unit
Hide thumbs Also See for 7975:
Table of Contents

Advertisement

Table 2. Synchronous Data Port Options (1 of 2)
7975-A2-GZ41-00
Port Type
Possible Settings: E530A, V.35, RS449, X.21
Default Setting: E530A
Determines the port type for the data port.
Payload Rate
Possible Settings: 64, 128, 192, 256, 320, 384, 448, 512, 576, 640, 704, 768, 832, 896,
960, 1024, 1088, 1152, 1216, 1280, 1344, 1408, 1472, 1536, 1600, 1664, 1728, 1792,
1856, 1920, 1984, 2048
Default Setting: 128
NOTE:
Payload rates of 1088 kbps and higher pertain only to the 2 Mbps
termination unit.
Specifies the payload rate of the port. This option is not displayed on the unit when
AutoRate is enabled or the unit is configured as an NTU. The LTU configures the
payload rate for the NTU when AutoRate is disabled.
Transmit Clock Source
Possible Settings: Internal, External
Default Setting: Internal
Specifies whether the transmitted data for the synchronous data port is clocked using an
internal clock provided by the LTU (synchronized to the clock source specified by the
clock source configuration option) or an external clock provided by the DTE connected
to the synchronous data port. If an external clock is used, it must be synchronized to the
same clock source as the LTU.
Invert Transmit Clock
Possible Settings: Disable, Enable
Default Setting: Disable
Specifies whether the clock supplied by the 7975 Termination Unit on the TXC
interchange circuit DB (CCITT 114) is phase inverted with respect to the Transmitted
Data interchange circuit BA (CCITT 103). This configuration option is useful when long
cable lengths between the 7975 Termination Unit and the DTE are causing data errors.
Send All Ones on Data Port Not Ready
Possible Settings: Both, Disable, DTR, RTS
Default Setting: Both
Specifies the conditions on the data port that determine when valid data is not being
sent from the DTE. When this condition is detected, all ones are sent to the network.
Action on Network LOS Alarm
Possible Settings: Halt, None
Default Setting: Halt
Specifies the action taken on the synchronous data port when an LOS (Loss Of Signal)
alarm is received on the network interface.
Network Initiated Data Channel Loopback
Possible Settings: Disable, Enable
Default Setting: Disable
Allows the initiation and termination of a Data Channel Loopback (DCLB) by the receipt
of a DCLB-actuate sequence or DCLB-release sequence from the network or far-end
device.
March 1999
9