Hyundai HG2700-1 Original Instructions Manual
Hyundai HG2700-1 Original Instructions Manual

Hyundai HG2700-1 Original Instructions Manual

Open frame petrol generator

Advertisement

Quick Links

OPEN FRAME PETROL GENERATOR
H G2700-1
WARNING: Read thoroughly the instruction manual before use.

Advertisement

Table of Contents
loading

Summary of Contents for Hyundai HG2700-1

  • Page 1 OPEN FRAME PETROL GENERATOR H G2700-1 WARNING: Read thoroughly the instruction manual before use.
  • Page 2: Table Of Contents

    CONTENT SAFETY INSTRUCTION COMPONENT IDENTIFICATION ASSEMBLY CONTROLS GENERATOR USE PRE-OPERATION CHECK STARTING / STOPPING THE ENGINE MAINTENANCE TRANSPORTING AND STORAGE TROUBLESHOOTING WIRING DIAGRAM SPECIFICATIONS EC DECLARATION OF CONFORMITY WARRANTY PRODUCT FAILURE WARRANTY EXCLUSIONS...
  • Page 3: Safety Instruction

    1. SAFETY INSTRUCTION Warning: 1. Attention! Exhaust gases are toxic. Do not operate the generator in a room without ventilation system! 2. Children should be protected by keeping them at a safe distance from the generator set! 3. Refilling of the generating sets is not allowed during the operation! 4.
  • Page 4 Perform periodic maintenance and resolve problems that appear immediately. Do not run the  generator before correcting any fault detected. The generator uses a system of air-cooling, and it is necessary to clean its components regularly,  including the grilles, the cover of the fan and the fan itself so as to ensure cooling. Keep the fuel filter clean, and change the oil of the motor regularly.
  • Page 5 The user must respect the requirements and precautions in the case of resupply by generating sets  of an installation, depending on existing protective measures in this installation and applicable regulations. Generating sets should only be loaded up to their rated power under the rated ambient conditions. ...
  • Page 6 applicable laws and norms in the field of electricity. Incorrect connections will cause leakage of the current from the generator into the lines of the public electricity company. Such leakage could electrocute the workers of the public electricity company working on the network or other persons in contact with the line during a power cut.
  • Page 7: Component Identification

    Danger! Electrical shock! Exhaust emissions are harmful to health of body No naked fire near the machine! This symbol indicates the surface is very hot and not touching 2. COMPONENT IDENTIFICATION NOTE: Diagrams may vary according to the types.
  • Page 8: Assembly

    3. ASSEMBLY 3.1 FEET Place a foot under each support. Screw the foot with a screw and a nut. Place the foot support under each side of the support bar (on the side where the starter grip is located). Screw the brackets together with a screw and nut. 3.2 WHEELS On the other side of the unit, insert the bar into the wheel mounting bracket.
  • Page 9 NOTICE Do not allow the starter to snap back against the engine. Return it gently to prevent damage to the starter. 4.3FUEL VALVE The fuel valve is located between the fuel tank and carburetor. When the valve lever is in the ON position, fuel is allowed to flow from the fuel tank to the carburetor.
  • Page 10: Generator Use

    4.6 GROUND TERMINAL The generator ground terminal is connected to the panel of the generator, the metal non-current carrying parts of the generator, and the ground terminals of each receptacle. Before using the ground terminal, consult a qualified electrician, electrical inspector or local agency having jurisdiction for local codes or ordinances that apply to the intended use of the generator.
  • Page 11 Special Requirements There may be Federal or State Occupational Safety and Health Administration (OSHA) regulations, local codes, or ordinances that apply to the intended use of the generator. Please consult a qualified electrician, electrical inspector, or the local agency having jurisdiction. •...
  • Page 12 5.5 DC OPERATION (IF AVAILABLE) DC Terminals The DC terminals may ONLY be used for charging 12 volt automotive type batteries. The terminals are colored red to identify the positive (+) terminal and black to identify the negative (-) terminal. The battery must be connected to the generator DC terminals with the proper polarity (battery positive to generator red terminal and battery negative to the generator black terminal).
  • Page 13: Pre-Operation Check

    4) Disconnect the positive (+) battery cable from the generator positive (+) terminal. 5) Disconnect the other end of the positive (+) battery cable to the battery positive (+) terminal. 6) Connect the vehicle ground cable to the battery negative (-) terminal. 7) Reconnect the vehicle grounded battery cable.
  • Page 14 6.2 FUEL RECOMMENDATION 1. Check the fuel level gauge. 2. Refill the tank if the fuel level is low. Do not fill above the shoulder of the fuel strainer. WARNING • Gasoline is extremely flammable and is explosive under certain conditions. •...
  • Page 15: Starting/Stopping The Engine

    Oxygenated Fuels Some gasoline is blended with alcohol or an ether compound to increase the octane. This gasoline is collectively referred to as oxygenated fuels. Some areas of the United States use oxygenated fuels to help meet clean air standards. If you use an oxygenated fuel, be sure its pump octane rating is 86 or higher.
  • Page 16: Maintenance

    7.2 STOPPING THE ENGINE In an emergency: To stop the engine in an emergency, move the engine switch to the OFF position. In normal use: 1. Turn the AC circuit breaker to the OFF position. Disconnect the DC battery charging cables. 2.
  • Page 17 The maintenance schedule applies to normal operating conditions. If you operate your generator under severe conditions, such as sustained high-load or high-temperature operation, or use it in unusually wet or dusty conditions, consult your servicing dealer for recommendations applicable to your individual needs and use.
  • Page 18 8.4 AIR CLEANER SERVICE A dirty air cleaner will restrict air flow to the carburetor. To prevent carburetor malfunction, service the air cleaner regularly. Service more frequently when operating the generator in extremely dusty areas. WARNING Using gasoline or flammable solvent to clean the filter element can cause a fire or explosion.
  • Page 19 8.5 FUEL SEDIMENT CUP CLEANING The sediment cup prevents dirt or water which may be in the fuel tank from entering the carburetor. If the engine has not been run for a long time, the sediment cup should be cleaned. 1) Turn the fuel valve to the OFF position.
  • Page 20: Transporting And Storage

    NOTICE The spark plug must be securely tightened. An improperly tightened spark plug can become very hot and could damage the engine. Never use spark plugs which have an improper heat range. Use only the recommended spark plugs or equivalent. 9.
  • Page 21 The fuel of this machine is combustible and deflagrating. After the machine has been shut down, the additional fuel must be treated properly and the local environmental requirements must be met. 2) Change the engine oil 3) Remove the spark plug, and pour about a tablespoon of clean engine oil into the cylinder. Crank the engine several revolutions to distribute the oil, and then reinstall the spark plug.
  • Page 22: Troubleshooting

    10. TROUBLESHOOTING When the engine will not start: Is there fuel in the tank? Refill the fuel tank Is there oil in the tank? Add the recommended oil. STILL SPARK Is there spark from Replace the Take the generator to an spark plug.
  • Page 23: Wiring Diagram

    11. CIRCUIT DIAGRAM...
  • Page 24: Specifications

    12. SPECIFICATIONS Engine Engine model PT170F1 Engine type Single cylinder, 4-strokes, Forced air cooling, OHV. Displacement( CC) 212cc Rated speed 3000/min Igniting system Transistor magneto Starting system Recoil Fuel Volume (L) 15 L Continuous operation time (h) 10.5 h Min. Fuel consumption (g/kWh) 360 g/kWh Lube Oil capacity (L) 0.6 L...
  • Page 25: Ec Declaration Of Conformity

    BUILDER SAS ZI, 32 RUE ARISTIDE BERGES – 312070 CUGNAUX – FRANCE Declares that the machinery designated below: OPEN FRAME PETROL GENERATOR Model: HG2700-1 Serial number: 20220616298-20220616522 Complies with the provisions of the Directive “machinery” 2006/42/CE and national laws transposing it:...
  • Page 26: Warranty

    14. WARRANTY WARRANTY The manufacturer guarantees the product against defects in material and workmanship for a period of 2 years from the date of the original purchase. The warranty only applies if the product is for household use. The warranty does not cover breakdowns due to normal wear and tear. The manufacturer agrees to replace parts identified as defective by the designated distributor.
  • Page 27: Product Failure

    15. PRODUCT FAILURE WHAT TO DO IF MY MACHINE BREAKS DOWN? If you bought your product in a store: a) Empty the fuel tank if your product has one. b) Make sure that your machine is complete with all accessories supplied, and clean! If this is not the case, the repairer will refuse the machine.
  • Page 28: Warranty Exclusions

    16. WARRANTY EXCLUSIONS THE WARRANTY DOES NOT COVER: • Start-up and setting up of the product. • Damage resulting from normal wear and tear of the product. • Damage resulting from improper use of the product. • Damage resulting from assembly or start-up not in accordance with the user manual. •...

Table of Contents