Zhone ETHX-2214-DS3 Installation Instructions Manual
Zhone ETHX-2214-DS3 Installation Instructions Manual

Zhone ETHX-2214-DS3 Installation Instructions Manual

Etherxtend ds3 ethernet access device

Advertisement

ETHX-2214-DS3 and ETHX-2224-DS3
EtherXtend DS3 Ethernet Access Device
Installation Instructions
Document Number ETH3-A2-ZN10-10
Issue 2 - August 2008
Contents
Software and Firmware License Agreement ..................................................... 2
Introduction to ETHX-2214-DS3 and ETHX-2224-DS3 .................................... 4
Package Contents ............................................................................................. 6
Release Notes ................................................................................................... 6
Product Documentation Online ......................................................................... 6
Powering Up the Network Extender .................................................................. 7
Connecting the DS3 Lines................................................................................. 9
Connecting the Ethernet Lines ........................................................................ 11
LED Indicators ................................................................................................. 12
Web Interface .................................................................................................. 14
Command Line Interface ................................................................................. 19
Resetting the Network Extender to Factory Defaults ...................................... 21
Specifications .................................................................................................. 23
Safety Notices ................................................................................................. 24
EMI Notices ..................................................................................................... 24
NEBS Compliance........................................................................................... 24
Service and Repair .......................................................................................... 25
Important Safety Instructions........................................................................... 26
1

Advertisement

Table of Contents
loading

Summary of Contents for Zhone ETHX-2214-DS3

  • Page 1: Table Of Contents

    Document Number ETH3-A2-ZN10-10 Issue 2 - August 2008 Contents Software and Firmware License Agreement ... 2 Introduction to ETHX-2214-DS3 and ETHX-2224-DS3 ... 4 Package Contents ... 6 Release Notes ... 6 Product Documentation Online ... 6 Powering Up the Network Extender ... 7 Connecting the DS3 Lines...
  • Page 2: Software And Firmware License Agreement

    Zhone or its authorized distributor or reseller under the following terms and conditions: 1. Ownership: The Software is the sole property of Zhone and/or its licensors. The Licensee acquires no title, right or interest in the Software other than the license granted under this Agreement.
  • Page 3 5. Except for the Product warranty contained in the manual, the Software is provided “AS IS” and in its present state and condition and Zhone makes no other warranty whatsoever with respect to the Product purchased by you. THIS AGREEMENT...
  • Page 4: Introduction To Ethx-2214-Ds3 And Ethx-2224-Ds3

    Net-to-Net (N2N) loop bonding protocol, which offers automatic, efficient, resilient, and configuration-free deployment with greater total throughput capacity than a traditional DS3 circuit. Zhone's loop bonded technology provides automatic load balancing and fail-over for optimum redundancy and data throughput.
  • Page 5: Subscriber Unit

    Provider vs Subscriber Units The EtherXtend 2200 DS3 units can be operated in either a Provider or Subscriber mode. A Subscriber unit is always considered as a ‘slave’ to the Provider unit, which acts as a ‘master’ when enabling the DS3 ports and loop bonding configurations. Therefore when using the ETHX-22x4-DS3 devices in a network, one Provider and one Subscriber unit are required on the unframed DS3.
  • Page 6: Package Contents

    Complete documentation for Zhone products is available at http://www.zhone.com/. Select Service & Support, and then select Documentation. http://www.zhone.com/support/manuals/ To order a paper copy of a Zhone document, or to speak with a sales representative, please call (877) 946-6320 (i.e. 877-ZHONE20). Provider Unit 192.168.254.252...
  • Page 7: Powering Up The Network Extender

    Powering Up the Network Extender The DC power terminal block on the network extender has five terminals: two positive, two negative, and one with no connection (NC). Only one positive terminal and one negative terminal pair need to be connected for operational purposes. The second positive and negative terminal pair may be connected to a backup DC power supply for redundancy purposes.
  • Page 8 Power Connection – AC Power 1. The AC power supply is shipped with the power terminal strip already attached. No AC power supply other than the one supplied with the ETHX-22x4-DS3 is approved for use in powering the unit. Using any other AC power supply could cause the unit to be non-compliant to emissions and safety regulations.
  • Page 9: Connecting The Ds3 Lines

    Connecting the DS3 Lines The ETHX-2214-DS3 device supports a single, unframed DS3 facility while the ETHX- 2224-DS3 device supports up two (2) unframed DS3 facilities. The ETHX-2224-DS3 device can be operated with just one of the two DS3s connected, or can be used in loop bonded applications where both DS3 circuits are utilized.
  • Page 10 ETHX-2224-DS3 Provider unit. Likewise, a single line connection can be established between a single port Provider unit and either a single port or dual port ETHX-2214-DS3 Subscriber unit. Procedure 1. Plug two coax cables, one for transmit (Tx) and one for receive (Rx), into the DS3 BNC 75 ohm port on the back of the network extender.
  • Page 11: Connecting The Ethernet Lines

    Connecting the Ethernet Lines The 10/100BaseT Ethernet ports can auto-negotiate speed and duplex mode in accordance with the remote equipment to which it is connected. Alternatively, Ethernet speed and duplex mode configurations can be configured using web management. (See Web Interface on page 14.) For the best connection results, the remote devices (PCs, hubs, or switches) should be set to auto-negotiate speed and duplex mode.
  • Page 12: Led Indicators

    LED Indicators Table 2. DS3 LEDs State Flashing Connections Green* LINK/ACT Solid Green (Ports 1 or 1&2) Solid Amber Pulsing Amber Flashing Connections Amber Tx (Ports 1 or 1&2) Illuminated Flashing Connections Amber Rx (Ports 1 or 1&2)) Illuminated Power Solid Green * A pulsing LED blinks steadily at a rate of once per second.
  • Page 13 Table 3. Ethernet LEDs State 10/100 Pulsing Ethernet Green Connections Solid LINK/ACT Green Illuminated 10/100 Solid Ethernet Amber Connections Duplex/ Illuminated Collision Pulsing Amber 10/100 Solid Ethernet Green Connections Illuminated Indication Standard operation Ethernet connection is established No Ethernet connection Full duplex Ethernet connection.
  • Page 14: Web Interface

    Web Interface The network extender’s integral web management lets you configure and monitor the network extender using a standard web browser. Web Interface System Requirements Web Browser – Required for running web management. Compatible web browsers include, but are not limited to, Microsoft Internet Explorer (v4.0 or higher) and Netscape Navigator (v4.0 or higher).
  • Page 15 5. Write down the current IP Address and Subnet Mask in the Internet Protocol (TCP/IP) Properties dialog box. When you are done using web management, you will need to reconfigure your PC with these values. 6. In the Internet Protocol (TCP/IP) Properties dialog box, click in the radio button labeled Use the following IP address and type 192.168.254.x (where x is any number between 3 and 250, inclusive) in the IP Address field.
  • Page 16 From this screen you can: Click on . . . Management Config. Advanced Config. HTTP Password SNMP Config. SNMP Community Pro/Sub Cfg IGMP Srvr Password Time-out Set DSLAM Users Show Help Refresh Screen Ethernet Connections Lnk/Act LEDs DS3 Connections Lnk/Alm LEDs Using Web Management to managing a Provider Unit To manage a Provider unit using web management, connect your PC to any Ethernet port of the Provider unit.
  • Page 17 Establishing an Static ARP Table Entry for a Subscriber Unit The Subscriber unit’s DS3 ports will not respond to an ARP request containing the unit’s default IP address. In order to manage the Subscriber unit using web management you must create a static ARP table entry on your PC. To build a static ARP table entry: Procedure Note –...
  • Page 18 Observe the designation displayed on the top-right side of graphical view of the front of the unit (just under the Zhone Logo). It will display either the word “Provider” or “Subscriber” indicating the current mode of the unit.
  • Page 19: Command Line Interface

    Command Line Interface The network extender can be managed with a Command Line Interface (CLI) through either a direct PC to COM (Communication) Port connection or from a remote network connection via Telnet. CLI System Requirements Straight-Through 8-Pin Modular Ethernet Cable – Required for establishing a direct connection from the COM port to a DB9 adapter.
  • Page 20: Logging Into The Cli

    Launching the Terminal Emulation Program Launch a terminal emulation program on your PC and configure the program settings. The terminal emulation software should be configured as follows (refer to your terminal emulation program’s user manual for further information). Baud: Data Bits: Flow Control: Parity: Logging into the CLI...
  • Page 21: Resetting The Network Extender To Factory Defaults

    Resetting the Network Extender to Factory Defaults The network extender supports a reset process that may be used to delete the current configuration and return it to the factory defaults, including the default password. Procedure To return the network extender to its factory default configuration: 1.
  • Page 22: Connector Pin Assignments

    Connector Pin Assignments Ethernet Pin Assignments Table 4. Ethernet Pin Assignments Function Pin 1 Pin 2 Rx– Pin 3 Pin 4 not used Pin 5 not used Pin 6 Tx– Pin 7 not used Pin 8 not used DB9 to 8-Pin Modular Adapter Pin Assignments To connect the COM port to the DB9 serial port of a PC, use an adapter wired as shown: Table 5.
  • Page 23: Specifications

    1.9" x 8.6" x 6.75" (H x W x D) 4.8 cm x 21.7 cm x 17.1 cm (H x W x D) Interfaces ETHX-2214-DS3: Two (2) BNC 75 ohm jacks (Tx and Rx) ETHX-2224-DS3: Four (4) BNC 75 ohm jacks (2-Tx and 2-Rx) Four (4) 10/100BaseT RJ45 Operating Environment Temperature: -40°...
  • Page 24: Safety Notices

    The authority to operate this equipment is conditioned by the requirements that no modifications will be made to the equipment unless the changes or modifications are expressly approved by Zhone Technologies, Inc. If the equipment includes a ferrite choke or chokes, they must be installed per the installation instructions.
  • Page 25: Service And Repair

    For additional information concerning warranty, sales, service, repair, installation, documentation, training, distributor locations, or Zhone worldwide office locations, use one of the following methods: Internet: Visit the Zhone World Wide Web site at www.Zhone.com.
  • Page 26: Important Safety Instructions

    Important Safety Instructions 1. Read and follow all warning notices and instructions marked on the product or included in the manual. 2. Do not allow anything to rest on the power cord and do not locate the product where persons will walk on the power cord. 3.
  • Page 27 Copyright 2008 Zhone Technologies, Inc. Printed in U.S.A.
  • Page 28 **** ETH3-A2-ZN10-10 **** **** 830-01728-02...

This manual is also suitable for:

Ethx-2224-ds3

Table of Contents