4.3 Judgment Output Setting
4.3.1 Judgment Hysteresis
Determine the hysteresis of the upper and lower limit values.
Enter the value corresponding to the display.
area).
Enter the setting corresponding to the displayed value.
4.3.2 Output Style Selection
The output style of the open collector output (HI, GO and LO) issued upon
deviation from the tolerance judgment value can be selected.
Function No.
N.O. normally open
N.C. normally closed
Ramco Innovations www.ramcoi.com
Enter the value so that the following equation stands true:
Upper limit value (H-thr) - hysteresis width (o-hys) > Lower limit value
(L-thr) + hysteresis width (o-hys)
POINT
Name
N.O. output
N.C. output
For the judgment hysteresis and output style selection method, refer to
Reference
page 75.
Description of action
The tolerance judgment output is issued from a N.O.
contact (contact A).
The tolerance judgment output is issued from a N.C.
contact (contact B).