Fault Diagnosis - Kohler Mira Sport Installation And User Manual

Hide thumbs Also See for Mira Sport:
Table of Contents

Advertisement

Fault Diagnosis

If the malfunction has not been detailed in the fault finding table or it was not
possible to correct the malfunction, professional assistance may be required. Any
fault diagnosis remedies MUST be carried out by a competent person or contact
Mira Customer Services to arrange a service engineer.
Power
Symptom
Control
Position
Shower fails
ANY
to operate
Shower
ECO/
cycles from
HIGH
hot to cold
Unable to
select a
ECO/
cool enough
HIGH
shower
Low flow
ANY
Operation of
Temperature
Control
ECO/
has little or
HIGH
no effect
on water
temperature
Possible Cause
Isolator switch in the off
position.
Fuse blown or MCB/RCD
tripped, indicating possible
electrical fault.
The hose or showerhead is
blocked.
W a t e r p r e s s u r e b e l o w
minimum required for shower
operation.
Temperature control or heater
setting too high.
Due to high water supply
tempera ture, the h ea te r
setting may be too high.
The hose or showerhead is
blocked.
The hose or showerhead is
blocked.
Other outlets (e.g. toilet,
g a r d e n h o s e , w a s h i n g
machine, etc.) drawing water
while the shower is being
used.
The hose or showerhead is
blocked.
23
Possible Remedy
Switch on electrical supply via the pullcord
or wall mounted switch.
Renew the fuse or reset the MCB/RCD. If
fault persists, contact your installer.
De-scale showerhead, check hose for
kinks or damage and replace if necessary.
Refer to the 'USER MAINTENANCE'
section of this guide.
Make sure incoming mains water stopcock
and/or shower isolating valve is fully
turned on.
Turn the power control to Eco or turn
the temperature control until a cooler
temperature is achieved.
Turn the power control to Eco or turn
the temperature control until a cooler
temperature is achieved.
De-scale showerhead, check hose for
kinks or damage and replace if necessary.
Refer to the 'USER MAINTENANCE'
section of this guide.
De-scale showerhead, check hose for
kinks or damage and replace if necessary.
Refer to the 'USER MAINTENANCE'
section of this guide.
Turn off other appliances whilst shower
is in use.
De-scale showerhead, check hose for
kinks or damage and replace if necessary.
Refer to the 'USER MAINTENANCE'
section of this guide.
1561662-W2-A