Af Illumination Check - Sony Cyber-shot DSC-P2 Service Manual

Level 2
Hide thumbs Also See for Cyber-shot DSC-P2:
Table of Contents

Advertisement

DSC-P2

21. AF Illumination Check

Check the deviation of optical axis of AF illuminator.
Mode
Subject
Measurement Point
Measuring Instrument
Note 1: Perform checking by making the shooting surface of the
Flash adjustment box perpendicular to the optical axis of
the camera.
Note 2: Perform this checking in the Flash adjustment box.
Restrict external light to enter the Flash adjustment box
as less as possible.
Note 3: Refer to "4. Preparing the Flash adjustment box".
(See page 5-7)
Switch setting
1) FOCUS (Menu setting) .............................. MULTI AF
Adjusting method:
Order Page Address Data
1
2
9
A9
3
6
01
4
6
02
5
F
10
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
RadarW
RadarW
RadarW
RadarW
RadarW
CAMERA
Flash adjustment box (Note 3)
(50 cm or 1 m from the front of
lens)
Check operation on monitor TV
Procedure
Perform "Data setting during
camera system adjustment".
(Refer to page 5-14)
Set the following data, and
press PAUSE button.
06: 50 cm
04: 1 m
EF
Press PAUSE button.
Check the data changes to
"01".
Check the data.
00: Normal
01 to FF: Defective
Procedure
00
Press PAUSE button.
Release the data setting
performed at step 1.
(Refer to page 5-14)
5-32

Advertisement

Table of Contents
loading

Table of Contents