Kohler 15C/12.5CF Operation page 23

Marine generator sets
Hide thumbs Also See for 15C/12.5CF:
Table of Contents

Advertisement

Service Schedule—Continued
Perform Service at Intervals Indicated (X)
INTAKE/EXHAUST SYSTEM, ETC.
Inspect exhaust system components [
Check the exhaust gas condition.
Service backfire flame arrestor
Clean the exhaust/water mixing elbow [
Check the crankcase breather hose for
[
obstructions
Inspect the complete exhaust system ***
ELECTRICAL SYSTEM
Keep battery charged and in good condition Å
Check and tighten electrical connections
Clean battery cables [
ENGINE AND MOUNTING
Check for water, fuel, coolant, and oil leakage
Retighten all nuts and bolts
Check tightness of mounting bolts/vibromounts
Check intake/exhaust valve clearance
Retighten cylinder head bolts
Torque intake manifold bolts
REMOTE CONTROL SYSTEM, ETC.
Check remote control operation
Test run generator set
GENERATOR
Blow dust out of generator [
[
Consult your local distributor/dealer for service.
]
Read WARNING found at the beginning of manual regarding moving parts.
*** Should be performed by your local distributor/dealer.
Å
Consult battery manufacturer's instructions.
TP-5981 11/01
Reference
Section
[
[]
[
[
[
After
50 Hrs
Before
or
Starting
1 Month
3.6
X
X
3.6
(during
operation)
3.5
3.6
2.2
3.10
X
X
X
2.6.3
(break-in
period)
2.5
(weekly)
3.1
Every
Every
100 Hrs
400 Hrs
or
or
3 Months
6 Months
X
X
(200 hrs)
X
X
X
X
(200 hrs)
X
(200 hrs)
X
X
X
Section 3 Scheduled Maintenance
Every
500 Hrs
or
Yearly
X
X
X
(800 hrs)
X
X
11