2.
MECHANICAL ADJUSTMENTS
PRECAUTION
1.
Clean
the following
parts with
a denatured-alcohol-
moistened swab:
record/playback head
pinch roller
erase head
rubber belts
capstan
idlers
2.
Demagnetize
the record/playback
head
with
a head
demagnetizer. (Do not bring the head demagnetizer close
to the erase head.)
3.
Do not use a magnetized screwdriver for the adjustments.
4.
After the adjustments, apply suitable locking compound
to the parts adjusted.
5.
The adjustments
should be performed
with the rated
power supply voltage unless otherwise noted.
6.
Power supply voltage: 12V dc.
Torque Measurement
Meter reading
22—55g*cm
ee
(0.31 = 0.76
02° inch)
Forward
2—5g°cm
sie
(0.028 oe. 0.069
02" inch)
Fast
more than 45g-cm
(more than 0.62 oz*inch)
Tape Tension Measurement
[wose [Meter id
Meter Reading
more than 100g
(more than 1.39 oz)
3.
ELECTRICAL ADJUSTMENTS
1.
TAPE RECORDER SECTION
Standard Output Level
Output terminal
SP OUT
HP OUT
omTsv (ab) _| 025 (-10aB)
Test Tape
ee
Tape Speed Adjustment
Procedure :
speed checker
Mode:
playback
LF ping
digital frequency
test tape
counter
WS-48A
(3kHz, OdB)
Ea
=
——
set
CD
-
3
fl
—- +
Phones jack
Adjustment Value:
Speed checker
Digital frequency counter
—13% to +0%
2,960 to 3,000Hz
Frequency difference between the beginning and the end of
the tape should be within 1.5% (45Hz).
Adjustment Location :
tape speed adjustment