Down-draft table with fan for welding and grinding

Advertisement

Quick Links

DOWN-DRAFT TABLE
WITH FAN FOR WELDING AND GRINDING
SAFETY INSTRUCTIONS FOR USE AND MAINTENANCE
EDITION
: EN
REVISION : A
DATE
: 10-2022
DOWN-DRAFT TABLE
N° W000273086 - W000273087
Instructions for use
8695 8014
REF :
Original instructions

Advertisement

Table of Contents
loading

Summary of Contents for Lincoln Electric W000273086

  • Page 1 DOWN-DRAFT TABLE DOWN-DRAFT TABLE WITH FAN FOR WELDING AND GRINDING SAFETY INSTRUCTIONS FOR USE AND MAINTENANCE N° W000273086 - W000273087 8695 8014 EDITION : EN Instructions for use REF : REVISION : A DATE : 10-2022 Original instructions...
  • Page 2 Thank for the trust you have expressed by purchasing this equipment, which will give you full satisfaction if you follow its instructions for use and maintenance. Its design, component specifications and workmanship comply with applicable European directives. Please refer to the enclosed CE declaration to identify the directives applicable to it.
  • Page 3: Table Of Contents

    8695 8014 CONTENTS A - INTRODUCTION .......................... 1 USING THE MANUAL ......................1 MACHINE GUARANTEE ......................1 ASSISTANCE ........................... 1 DESCRIPTION OF PICTOGRAMS ..................1 B - GENERAL SAFETY INSTRUCTIONS ..................2 ELECTRICAL SAFETY ......................2 PERSONAL PROTECTION ..................... 3 FILTRATION OF FUMES AND DUST ..................
  • Page 4 8695 8014 DOWN-DRAFT TABLE...
  • Page 5 ASMV Down-draft table DOWN-DRAFT TABLE WITH FAN FOR WELDING AND GRINDING TYPE : W000273087 and W000273086 1) CE/UE DECLARATION OF CONFORMITY Dear customer, This CE/EU declaration of conformity certifies that the supplied equipment complies with applicable laws and regulations when used in accordance with the enclosed instructions. Any other assembly or modification would void our certification.
  • Page 6 8695 8014 DOWN-DRAFT TABLE...
  • Page 7: A - Introduction

    Before the filter is used by a new user, make sure that they have read this manual and understood all the explanations provided. For any further information, please feel free to contact the technical departments of LINCOLN ELECTRIC. MACHINE GUARANTEE This machine is guaranteed for 12 months from the date of purchase.
  • Page 8: B - General Safety Instructions

    8695 8014/A B - GENERAL SAFETY INSTRUCTIONS ELECTRICAL SAFETY Connection to the mains Before you connect your machine, please make sure that: The meter, the overintensity protection system and the electrical installation are compatible with its maximum power rating and its supply voltage. It can be connected, in a single-phase or three-phase with earth system, to a socket compatible with the plug on its power cord (mobile equipment).
  • Page 9: Personal Protection

    8695 8014/A PERSONAL PROTECTION Risks of external injury relating to welding operations Whole body The operator must be clothed and protected to suit the requirements of the job. Make sure that no part of the bodies of operators and helpers can come in contact with metal pieces or parts that are live or are liable to become live accidentally.
  • Page 10 8695 8014/A Specific case of chlorine solvents in welding: (used for cleaning or degreasing). The fumes from these solvents can be changed into toxic gases when subjected to arc radiation, including from a distance. Such solvents may therefore not be used in locations where electric arcs occur, if the solvents are not in a sealed enclosure.
  • Page 11: Filtration Of Fumes And Dust

    Not obstruct the air outlet of the machine. Not introduce external elements into the filter (paper, cloths, cigarette butts etc.) Replace the filter medium with new original LINCOLN ELECTRIC medium, which alone can guarantee the filtration characteristics. Replace the hoses if they are pierced.
  • Page 12: C - Overall Description

    2000 x 800 mm Part numbers ASMV down-draft table, 1200 x 800 mm W000273087 ASMV down-draft table, 2000 x 800 mm W000273086 Rear lateral or vertical outlet, Ø 250 mm W000342588 Rear lateral or vertical outlet, Ø 250 mm W000273464 TRC Ø...
  • Page 13: D - Technical Description

    8695 8014/A D - TECHNICAL DESCRIPTION COMPOSITION OF THE ASMV TABLE The table is made up of:  A table top, 1070 X 740 or 1870 x 740 mm.  Working height 920 mm.  Max load capacity of the table: 200 kg. ...
  • Page 14: Dimensions Of The Asmv Table

    8695 8014/A DIMENSIONS OF THE ASMV TABLE ASMV table, 1200 x 800 mm Switch Discharge grill ASMV table, 2000 x 800 mm Switch Discharge grill DOWN-DRAFT TABLE...
  • Page 15: Operating Principle

    8695 8014/A OPERATING PRINCIPLE When the fan is started up, fumes and dust are extracted in two stages: 1. The fumes first pass through an air flow distribution plate to even the extraction between the work surface and lateral panels and then through the integrated metal pre-filter meeting the EU2 standard and measuring 610 x 610 x 24 mm.
  • Page 16 8695 8014/A HCAS FAN  HCAS low-pressure centrifugal fans are designed to extract clean air or air with a low dust and fumes content.  SPECIFICATIONS OF STANDARD RANGE Class F MOTOR, IP55, 50Hz, B35, 400V three phase Forward curved type IMPELLER in painted steel Painted steel HOUSING ...
  • Page 17: E - Installation Of The Asmv Table

    8695 8014/A E - INSTALLATION OF THE ASMV TABLE ASSEMBLY Move the table with a lift truck to its location, then remove the packaging and transport protection material. Connect the table to the air extraction duct using Ø 250 or 315 mm, for outdoor discharge. Electricity power must be provided nearby.
  • Page 18: F - Maintenance

    The performance of operations that may not be carried out or are contrary to the standards and procedures described in the manual would release LINCOLN ELECTRIC from liability for any damage caused and would void the guarantee if it is still valid.
  • Page 19: Pre-Filter

    8695 8014/A PRE-FILTER During pre-filter maintenance, always use protective goggles and a respiratory mask in order to prevent all risks of contact with or inhalation of the particles collected. The power supply must always be switched off using the disconnector or via the fuses. If the filter has a power connector, it must be separated from its socket on the wall. Pre-filter cleaning frequency Maintenance depends on use.
  • Page 20: Electrical Diagrams

    8695 8014/A ELECTRICAL DIAGRAMS DOWN-DRAFT TABLE...
  • Page 21: Spare Parts

    8695 8014/A SPARE PARTS Description Part number Quantity Lateral or rear vertical table outlet, 250 mm W000342588 Vertical outlet with silencer box W000273464 TRC Ø250 mm, 1200 x 800 mm table W000380507 TRC Ø315 mm, 2000 x 800 mm table W000380508 Metal pre-filter (610 x 610 x 24) mm W000379636...
  • Page 22: Personal Notes

    8695 8014/A PERSONAL NOTES Lincoln Electric France S.A.S. Avenue Franklin Roosevelt 76120 Le Grand Quevilly 76121 Le Grand Quevilly cedex www.lincolnelectriceurope.com DOWN-DRAFT TABLE...