Husqvarna EPOS RS1 Operator's Manual page 7

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Note:
The first weeks after installation the sound level
when the product cuts the grass can be higher than
usual. The sound level decreases after some time.
3.4 To examine where to put the
reference station
CAUTION:
If there is a lightning rod
near by, do not install the reference station
higher than the lightning rod.
CAUTION:
Do not install the reference
station on a flagpole. Movements of the
reference station will affect the correction
data sent to the product with the accurate
position.
Install the reference station on a fixed object that
cannot move or rotate.
Install the reference station on a post or a wall. The
post must be 27-36 mm / 1.1-2.2 in. in diameter to
fit the attachments on the reference station.
Note:
If the reference station is installed on a
wall the top of the reference station must be above
the wall. Metal objects can cause interference with
the reference station signal.
Make sure that the reference station has full view
of the sky. It is necessary that minimum 135
degrees of the sky has a full view.
135°
Install the reference station at minimum 2 m / 6.5
ft. height.
Make sure that the distance between the reference
station and the robotic lawn mower is less than
100 m / 330 ft. Objects between the reference
station and robotic lawn mower can decrease the
distance.
2211 - 002 - 30.11.2023
3.5 To examine where to put the power
supply
Put the power supply in an area with a roof and
protection from the sun and rain.
Put the power supply in an area with good airflow.
Use a residual-current device (RCD) when you
connect the power supply to the power outlet.
Extend the low-voltage cable if necessary. The
low-voltage cable can be extended up to 100 m /
328 ft.
3.6 To examine where to put the
charging station
You can put the charging station within the work
area or outside the work area. No transport path
is necessary if the charging station is put in the
work area (A). No transport path is necessary if
the product is fully in the work area when it is at
the charging station docking point. If the charging
station and docking point (B) are not in the work
area, you must install a transport path (C).
A
You can put the charging station in an
®
Automower
house.
Put the charging station (A) where the docking
point (B) has unimpeded sky view. The charging
station docking point (B) is where the product
stops after reversing from the charging station. The
reversing distance can be set to 70-250 cm / 28-98
in. Husqvarna recommends to have a minimum 6
m / 20 ft. (C) of free space in front of the charging
station.
C
B
B
C
A
Installation - 7

Advertisement

Table of Contents
loading

Table of Contents