Lighting The Unit; Turning Off The Gas To The Unit - Bradford White Brute BNTH1200 User Manual

Hide thumbs Also See for Brute BNTH1200:
Table of Contents

Advertisement

Page 4

LIGHTING THE UNIT

1. STOP! Read the safety information on the previous pages first!
2. Set the thermostat to the lowest setting.
3. Turn off all electric power to the unit.
4
This unit is equipped with an ignition device which automatically
lights the burner. Do not try to light the burner by hand.
5. Remove the front access panel.
6
Turn OFF the manual gas valve. The valve is off when the valve
handle is at a right angle to the gas pipe.
7. Wait five minutes to allow any gas to clear. Smell for gas,
including the area near the floor. If you do smell gas, STOP!
Follow Step B in the safety information listed above. If you don't
smell gas, go to the next step.
8. Slowly turn the manual gas valve to "ON." The handle on the
valve will be parallel to the gas pipe.
9. Replace the front panel.
10. Turn ON the electric power to the unit.
11. Set the thermostat to the desired setting.
12. If the unit will not operate, follow the instructions
in "Turning Off the Gas to the Unit" and call your
service technician or gas supplier.
TURNING OFF THE GAS TO THE
UNIT
1. Before doing any service work, turn
off all electric power to the unit.
2. Set the thermostat to the lowest
setting.
3. Remove the front access panel.
4. Turn OFF the manual gas valve.
The valve is off when the valve
handle is at a right angle to the gas
pipe.
5. Replace the front panel.
WARNING
Carbon Monoxide Hazard
This product burns gas to produce heat. The
appliance must be properly installed, operated, and
maintained to avoid exposure to appreciable levels
of carbon monoxide and the installer is required to
confirm that at least one carbon monoxide alarm is
installed in the living space before the appliance is put
into operation.
It is important for carbon monoxide alarms to be
installed, maintained, and replaced following the alarm
manufacturer's instructions and applicable local codes.
AVERTISSEMENT
Danger lié au monoxyde de carbone
Ce produit brûle des gaz pour produire de la chaleur.
L'appareil requiert une installation, un fonctionnement
et une maintenance adéquates afin d'éviter l'exposition
à des niveaux appréciables de monoxyde de carbone;
l'installateur est requis de confirmer qu'au moins une
alarme de détection de monoxyde de carbone est
installée dans l'espace de vie avant que l'appareil ne
soit mis en service.
Il importe que les alarmes de détection de monoxyde
de carbone soient installées, maintenues et remplacées
selon les directives du manufacturier et les codes
locaux applicables.
B
W
RADFORD
HITE
Gas inlet
Manual gas valve
shown in the
Off position

Advertisement

Table of Contents
loading

This manual is also suitable for:

Brute bnth1000Brute bntv1000Brute bntv1200