Carrier 59TP6C Installation, Start-Up, Operating And Service And Maintenance Instructions page 61

Two-stage, non-communicating, variable 25-speed, ecm multipoise, condensing gas furnace with intelisense
Table of Contents

Advertisement

59TP6C: Installation, Start-up, Operating and Service and Maintenance Instructions
a. Turn gas valve ON/OFF switch to OFF.
b. Loosen set screw on manifold tower pressure tap no more than
one full turn with a 3/32-in. hex wrench, or remove the 1/8 inch
NPT plug from the manifold pressure tap on the gas valve.
c. Connect a water column manometer or similar device to
manifold pressure tap.
d. Turn gas valve ON/OFF switch to ON.
e. On the 3 digit display, navigate to (Htt) and select (2St) to lock
furnace in low-heat operation. See
f. Manually close blower door switch.
g. Jumper R and W/W1 thermostat connections on control to start
furnace. See
Fig.
38.
h. Remove regulator adjustment cap from low heat gas valve
pressure regulator and turn low-heat adjusting screw (3/16 or
smaller flat-tipped screwdriver) counterclockwise (out) to
decrease input rate or clockwise (in) to increase input rate. See
Fig.
64.
!
DO NOT set low-heat manifold pressure less than 1.3-in. w.c. (324 Pa)
or more than 1.7 in. w.c. (423 Pa) for natural gas. If required manifold
pressure is outside this range, change main burner orifices to obtain
manifold pressure in this range.
i. Install low-heat regulator adjustment cap.
j. Leave manometer or similar device connected and proceed to
Step 2.
2. Adjust manifold pressure to obtain high fire input rate See
a. Jumper R to W/W1 and W2 thermostat connections on furnace
control. This keeps furnace locked in high-heat operation.
b. Remove regulator adjustment cap from high-heat gas valve
pressure regulator and turn high heat adjusting screw (3/16-in. or
smaller flat-tipped screwdriver) counterclockwise (out) to
decrease input rate or clockwise (in) to increase input rate. See
Fig.
64.
!
DO NOT set high-heat manifold pressure less than 3.2-in. w.c. (797 Pa)
or more than 3.8 in. w.c. (947 Pa) for natural gas. If required manifold
pressure is outside this range, change main burner orifices to obtain
manifold pressure in this range.
c. When correct input is obtained, replace caps that conceal gas
valve regulator adjustment screws. Main burner flame should be
clear blue, almost transparent See
Fig. 65 – Burner Flame
d. Remove jumpers R to W/W1 and R to W2.
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Fig.
38.
NOTICE
NOTICE
Fig.
65.
Clocking the Meter
3. Verify natural gas input rate by clocking meter.
NOTE: Contact your HVAC distributor or gas supplier for metric gas
meter tables, if required.
a. Turn off all other gas appliances and pilots served by the meter.
b. On the 3 digit display, navigate to (Htt) and select (2St). This
keeps furnace locked in low-heat operation when only W/W1 is
energized.
c. Jumper R to W/W1.
d. Run furnace for 3 minutes in low-heat operation.
e. Measure time (in sec) for gas meter to complete one revolution
and note reading. The 2 or 5 cubic feet dial provides a more
accurate measurement of gas flow.
f. Refer to
Table 25
SIZE OF TEST DIAL
SEC.
FOR 1
1 Cu
REV.
Ft.
10
360
11
327
12
300
13
277
14
257
15
240
16
225
17
212
18
200
Fig.
64.
19
189
20
180
21
171
22
164
23
157
24
150
25
144
26
138
27
133
28
129
29
124
30
120
31
116
32
113
33
109
34
106
35
103
36
100
37
97
38
95
39
92
40
90
41
88
42
86
43
84
44
82
45
80
46
78
47
76
48
75
49
73
A89020
g. Multiply gas rate cu ft./hr by heating value (BTUh/cu ft.) to
obtain input rate.
h. If clocked rate does not match required input from Step 1,
increase manifold pressure to increase input or decrease manifold
61
for cubic ft. of gas per hr.
Table 25 – Gas Rate (CU ft./hr)
SEC.
FOR 1
2 Cu
5
REV.
Ft.
Cu Ft.
720
1800
50
655
1636
51
600
1500
52
555
1385
53
514
1286
54
480
1200
55
450
1125
56
424
1059
57
400
1000
58
379
947
59
360
900
60
343
857
62
327
818
64
313
783
66
300
750
68
288
720
70
277
692
72
267
667
74
257
643
76
248
621
78
240
600
80
232
581
82
225
563
84
218
545
86
212
529
88
206
514
90
200
500
92
195
486
94
189
474
96
185
462
98
180
450
100
176
439
102
172
429
104
167
419
106
164
409
108
160
400
110
157
391
112
153
383
116
150
375
120
147
367
SIZE OF TEST DIAL
1 Cu
2 Cu
5 Cu
Ft.
Ft.
Ft.
72
144
360
71
141
355
69
138
346
68
136
340
67
133
333
65
131
327
64
129
321
63
126
316
62
124
310
61
122
305
60
120
300
58
116
290
56
112
281
54
109
273
53
106
265
51
103
257
50
100
250
48
97
243
47
95
237
46
92
231
45
90
225
44
88
220
43
86
214
42
84
209
41
82
205
40
80
200
39
78
196
38
76
192
38
75
188
37
74
184
36
72
180
35
71
178
35
69
173
34
68
170
33
67
167
33
65
164
32
64
161
31
62
155
30
60
150