Siemens SIMATIC NET SCALANCE XC-400 Operating Instructions Manual page 82

Industrial ethernet switches
Table of Contents

Advertisement

Technical specifications
9.3 Technical specifications of SCALANCE XC424-4
Technical specifications
Ambient temperature
2)
82
Property
With LAN operation with RJ45 plug
Up to 2000 m above sea level
When operating with plug-in trans‐
ceivers of the types:
SFP992-1
SFP992-1 (C)
SFP992-1LD
SFP992-1LD (C)
Up to 2000 m above sea level
When operating with plug-in trans‐
ceivers of the types
:
3)
SFP992-1+
SFP992-1LD+
SFP992-1LH
SFP992-1LH+
SFP992-1ELH
SFP992-1BXMT
SFP992-1BXMR
SFP992-1BX10T
SFP992-1BX10R
Up to 2000 m above sea level
When operating with plug-in trans‐
ceivers of the types:
SFP993-1
SFP993-1LD
Up to 2000 m above sea level
When operating with SFP transceiv‐
ers of the type
:
3)
SFP993-1LH
Up to 2000 m above sea level
With operation between 2000 m
and 3000 m above sea level
With operation between 3000 m
and 4000 m above sea level
Startup at -40 °C
During operation in horizontal installation posi‐
tion (position 1):
-40 °C to +60 °C
During operation in a different installation posi‐
tion (positions 2, 3 and 4):
-40 °C ... +50 °C
During operation in horizontal installation posi‐
tion (position 1):
-40 °C to +60 °C
During operation in a different installation posi‐
tion (positions 2, 3 and 4):
-40 °C ... +50 °C
During operation in horizontal installation posi‐
tion (position 1):
-40 °C to +55 °C
During operation with vertical mounting position
(position 2) or with ceiling mounting / face down
(position 3):
-40 °C ... +50 °C
During operation with floor installation / face up
(position 4):
-40 °C ... +40 °C
During operation in horizontal installation posi‐
tion (position 1):
-40 °C to +55 °C
During operation with vertical mounting position
(position 2) or with ceiling mounting / face down
(position 3):
-40 °C ... +50 °C
During operation with floor installation / face up
(position 4):
-40 °C ... +40 °C
During operation in horizontal installation posi‐
tion (position 1):
-40 °C ... +40 °C
The maximum ambient temperature is reduced
by 5 °C
4)
The maximum ambient temperature is reduced
by 10 °C
4)
Operating Instructions, 08/2023, C79000-G8976-C694-01
SCALANCE XC-400

Advertisement

Table of Contents
loading

Table of Contents