Download Print this page

Maintenance - Central Machinery 59477 Owner's Manual

Benchtop abrasive blast cabinet

Advertisement

user-Maintenance instructions
procedures not specifically explained in this manual must
be performed only by a qualified technician.
tO preVent SeriOuS inJury FrOM acciDentaL OperatiOn:
turn off the tool, detach the air supply, safely discharge any residual air pressure
in the tool, and release the throttle and/or turn the switch to its off position before
performing any inspection, maintenance, or cleaning procedures.
tO preVent SeriOuS inJury FrOM tOOL FaiLure:
Do not use damaged equipment. if abnormal noise, vibration,
or leaking air occurs, have the problem corrected before further use.
cleaning, Maintenance, and Lubrication
note: These procedures are in addition to the regular checks and maintenance
explained as part of the regular operation of the air‑operated tool.
1. BeFOre eacH uSe, inspect the general
condition of the tool. Check for:
• loose hardware or housing,
• misalignment or binding of moving parts,
• cracked or broken parts, and
• any other condition that may
affect its safe operation.
2. Daily - air Supply Maintenance:
Every day, maintain the air supply according
to the component manufacturers' instructions.
Drain the moisture filter regularly.
Performing routine air supply maintenance
will allow the tool to operate more safely
and will also reduce wear on the tool.
3. Quarterly (every 3 months) –
tool Disassembly, cleaning, and inspection:
Have the internal mechanism cleaned, inspected,
and lubricated by a qualified technician.
a. Disconnect the dust collection
system from the Blast Cabinet.
b. Disconnect Air Hose and Syphon
Hoses from the Gun.
Item 59477
For technical questions, please call 1-888-866-5797.
cleaning the Hopper
It is not necessary to remove the blasting medium
from the Hopper after every use. However,
clean out the Hopper when a different blasting
medium is to be used or when the medium
gets worn down. To clean the Hopper:
WarninG: Wear ANSI‑approved safety goggles,
full face shield and a NIOSH‑approved protective
dust mask or respirator when replacing the
abrasive medium in the Blast Cabinet.
1. Remove the Gun from the Cabinet.
2. Pull the Gloves through the glove holes so that they
are out of the way of the inside of the Blast Cabinet.
3. Remove the Grate from the Blast Cabinet.
4. Straddle the Blast Cabinet over two saw
horses (sold separately) with an open
container below which is large enough to
hold the abrasive material in the hopper.
5. Unthread the Cap (38) at the bottom
of the Hopper and allow the abrasive
medium to flow into the container.
6. Use your compressor set at 10 PSI to help blow
any excess abrasive out of the hopper and
into the container. Also, use the compressor
to clean abrasive out of the Blast Gun and
the Siphon Hose and Siphon Tube.
7. Replace the Cap and the Grate
once the Hopper is empty.
8. Push the Gloves back into the Blast Cabinet.
9. Reassemble the Siphon Hose, Siphon
Tube and Blast Gun and fill the Hopper
with new blasting medium.