Wiring Diagram - Sharp R-961 (W) Service Manual

Grill and convection microwave oven
Table of Contents

Advertisement

WIRING DIAGRAMS
SCHEMATIC
NOTE: CONDITION OF OVEN
1.DOOR CLOSED.
2." : "OR CLOCK APPEARS ON DISPLAY.
NOTE: * indicates components with potentials above 250 V.
MAGNETRON
THERMAL
CUT-OUT
THERMAL
CUT-OUT
POWER,
Tf].
HEATER
HV. RECTIFIER
*
NOISE
SUPPRESSION
COIL
* ASYMMETRIC
RECTIFIER
Figure O-1 Oven Schematic-OFF Condition
AC CORD CONNECTION
BRN : BROWN
BLU
: BLUE
G-Y
: GREEN AND
YELLOW STRIPE
/15
: SECTIONAL
AREA
OF 1.5mm2MIN.
SCHEMATIC
NOTE: CONDITION OF OVEN
1. DOOR CLOSED.
2. COOKING TIME PROGRAMMED.
3. MICROWAVE
KEY TOUCHED ONCE.
4. START KEY TOUCHED.
MAGNETRON
THERMAL,
CUT-OUT
THERMAL,
CUT-OUT
10M
/0.5W
TRANSFORMER
230V~S0Hz
POWER.
T/C TRANSFORMER,
HV. RECTIFIER
*
NOISE
SUPPRESSION
COIL
Figure O-2 Oven Schematic-Microwave Cooking Condition
R-961
-
37

Advertisement

Table of Contents
loading

This manual is also suitable for:

R-961 (k)