FDOOT221, FDO221, FDT221
Automatic fire detectors
addressable (FDnet)
The optimum smoke detector for all applications
Signal processing with detection algorithms (DA)
Early and reliable detection of emerging fires
High immunity to deceptive phenomena
Dual optical sensors for enhanced detection and failsafe operation
Communication via FDnet
Ecologic material concept
Building Technologies
Sinteso™
C-LINE
CPS Fire Safety

Advertisement

loading

Summary of Contents for Siemens Sinteso C-LINE FDOOT221

  • Page 1 FDOOT221, FDO221, FDT221 Sinteso™ C-LINE Automatic fire detectors addressable (FDnet) The optimum smoke detector for all applications  Signal processing with detection algorithms (DA)  Early and reliable detection of emerging fires  High immunity to deceptive phenomena  Dual optical sensors for enhanced detection and failsafe operation ...
  • Page 2 Characteristics Environmental  – ecologically processing – recyclable materials – electronic und synthetic material simple separable – ecologically beneficial detector testing without test gas Characteristics  – resistant to environment and interference factors such as dust, fibers, insects, humid- ity, extreme temperatures, electro-magnetic interference, corrosive vapors, vibration, synthetic aerosols and atypical fire phenomena –...
  • Page 3: Installation

    FDX291 Dummy detector Application  To cover bases without detectors over a long period – Installation Easy, time-saving and high-quality mounting  – base with stand-offs for surface and recess supply wiring – base without stand-offs for gap free ceiling mounting, only for recess supply wiring –...
  • Page 4 Technical data FDOOT221 FDO221 FDT221 Operating voltage (modulated) DC 12…33 V DC 12…33 V DC 12…33 V Operating current (quiescent) 200…280 µA 180…230 µA 130…200 µA Ext. alarm indicator without sounder base – Ext. alarm indicator with sounder base AI connectable and programmable Operating temperature -10…+60 °C -10…+60 °C...
  • Page 5 Details for ordering Type Part no Designation Weight FDOOT221 A5Q00001566 Multi-sensor smoke detector 0.107 kg FDO221 A5Q00001565 Smoke detector 0.101 kg FDT221 A5Q00001567 Heat detector 0.087 kg FDX291 S54319-F2-A1 Dummy detector 0.120 kg Detector and detector base accessories see data sheet 007775 Colored detectors, bases and base attachment see data sheet 009409 Details see equipment overview 008164 Details about system compatibility see List of compatibility 008331...
  • Page 6 Siemens Switzerland Ltd Infrastructure & Cities Sector Building Technologies Division International Headquarters © 2014 Copyright by CPS Fire Safety Siemens Switzerland Ltd Gubelstrasse 22 Data and design subject to change without notice. CH-6301 Zug Supply subject to availability. Tel. +41 41 724 24 24 www.siemens.com/buildingtechnologies...