Item
PC tuning mode
7. Open
1) Adj item: [Open Squelch
Squelch
(NXDN Very Narrow)]
adjust
[NXDN
2) Adj item:
Very
[L1],[L5],[C3],[H2],[H6]
Narrow]
SSG output: 12dB SINAD level
at Analog Narrow -3dB
(MOD: 400Hz/±1.2kHz)
8. Tight
1) Adj item: [Tight Squelch
Squelch
(Analog Narrow)]
adjust
[Analog
2) Adj item:
Narrow]
[L1],[L5],[C3],[H2],[H6]
SSG output:
12dB SINAD level +6dB
(MOD: 1kHz/±1.5kHz)
9.Tight
1) Adj item: [Tight Squelch
Squelch
(Analog Wide 5k)]
adjust
[Analog
2) Adj item:
Wide 5k]
[L1],[L5],[C3],[H2],[H6]
SSG output:
12dB SINAD level +6dB
(MOD: 1kHz/±3kHz)
10.Tight
1) Adj item: [Tight Squelch
Squelch
(Analog Wide 4k)]
adjust
[Analog
2) Adj item:
Wide 4k]
[L1],[L5],[C3],[H2],[H6]
(E2 type
only)
SSG output:
12dB SINAD level +6dB
(MOD: 1kHz/±2.4kHz)
11. RSSI
1) Adj item: [RSSI Reference
reference
(Analog Narrow)]
[Analog
Narrow]
2) Adj item:
[L1],[L5],[C3],[H2],[H6]
SSG output:
12dB SINAD level -3dB
(MOD: 1kHz/±1.5kHz)
12. Low
1) Adj item: [Low RSSI (Analog
RSSI
Narrow)]
2) Adj item:
[L1],[L5],[C3],[H2],[H6]
SSG output: -118dBm (0.28uV)
(MOD: 1kHz/±1.5kHz)
1-74 (No.RA094<Rev.002>)
Measurement
Test-
Unit
Terminal Unit Parts
equipment
SSG
RX ANT
Audio
Analyzer
Oscilloscope
RA (D-
SUB25
Pin No.11)
SSG
RX ANT
Audio
Analyzer
Oscilloscope
RA (D-
SUB25
Pin No.11)
SSG
RX ANT
Audio
Analyzer
Oscilloscope
RA (D-
SUB25
Pin No.11)
SSG
RX ANT
Audio
Analyzer
Oscilloscope
RA (D-
SUB25
Pin No.11)
SSG
RX ANT
Audio
Analyzer
Oscilloscope
RA (D-
SUB25
Pin No.11)
SSG
RX ANT
RA (D-
SUB25
Pin No.11)
Adjustment
Method
PC
After input signal from
ADJ
SSG, press [Apply]
button to store the
adjustment value.
PC
After input signal from
ADJ
SSG, press [Apply]
button to store the
adjustment value.
PC
After input signal from
ADJ
SSG, press [Apply]
button to store the
adjustment value.
PC
After input signal from
ADJ
SSG, press [Apply]
button to store the
adjustment value.
PC
After input signal from
ADJ
SSG, press [Apply]
button to store the
adjustment value.
PC
After input signal from
ADJ
SSG, press [Apply]
button to store the
adjustment value.