10 Maintenance

10.1 Periodic maintenance
The unit does not require specific maintenance. Only as a precautionary measure and in case of intensive use, it is
opportune to periodically (every six months) check that the electric cables are in good condition and that the bolts and nuts are
tight, and oil the contact areas between the fixed and mobile sliding pieces.
All checks must be recorded (in a dedicated record-book).
10.2 Problem solving
THE GATE DOES NOT MOVE:
- check the 120V AC power on the terminals L-N
- check the fuses
- check the 24 V power on terminals 10-11
- check the connection of the stop button; if not used, set the dip 10 to ON
- check the safety device connection (partial stop); if unused, set dip switch 8 to ON
- check that the small access panel for blocking/release is closed.
THE GATE REMAINS IN THE OPEN POSITION:
- automatic closure disabled, see dip no.1
- check all the command devices are working correctly
- ensure that nothing is obstructing the safety devices
- make sure all N.C. contacts are set to ON if not used.

11 Demolition and disposal

In its premises, CAME CANCELLI AUTOMATICI S.p.A. implements an Environmental Management System certified in
compliance with the UNI EN ISO 14001 standard to ensure environmental protection.
Please continue our efforts to protect the environment—which CAME considers one of the cardinal elements in the development
of its operational and market strategies—simply by observing brief recommendations as regards disposal:
DISPOSAL OF PACKAGING – The packaging components (cardboard, plastic, etc.) are all classifiable as solid urban waste
products and may be disposed of easily, keeping in mind recycling possibilities.
Prior to disposal, it is always advisable to check specific regulations in force in the place of installation.
PLEASE DISPOSE OF PROPERLY!
PRODUCT DISPOSAL – Our products are made up of various types of materials. Most of them (aluminium, plastics, iron,
electrical wires, etc.) may be disposed of in normal garbage collection bins and can be recycled by disposing of in specific
recyclable material collection bins and disposal in authorized centres. Other components (electrical boards, remote control
batteries, etc.), however, may contain polluting substances. They should therefore be removed and given to qualified service
companies for proper disposal.
Prior to disposal, it is always advisable to check specific regulations in force in the place of disposal.
PLEASE DISPOSE OF IN NATURE!
Standard for Door, Drapery, Gate, Louver, and Window Operators and Systems, UL 325 - 5th edition,
Issued 06/07/2002. Revised 08/29/2007.
Standard(s):
Standard for Operators and Systems of Doors, Gates, Draperies and Louvres, CSA C22.2 No. 247.
Issued 12/01/1992 (R2004), General Instruction No. 1
Product:
Vehicular Horizontal Slide-Gate Operators
Models:
BK Series: BK-810U, BK-1210U, BK-1810U, BK-2210U
Intertek Testing Services NA Inc.
165 Main Street, Cortland, NY 13045
Telephone 800-345-3851 or 607-753-6711 Fax 607-756-6699
CAME Cancelli Automatici S.p.A.
31030 Dosson di Casier - Treviso - ITALY
tel (+39) 0422 4940 - fax (+39) 0422 4941
internet: www.came.it - e-mail: info@came.it
via Martiri della Libertà, 15
23

Advertisement

loading