Samsung PS42P2SBX/XEC Service Manual page 49

Plasma display tv
Table of Contents

Advertisement

No
1
LVDS Connector
2
Operation LED
3
Key-Scan Connector
4
5
Y Connector
6
X Connector
7
LE01 (Address Buffer Connector)
8
LE02 (Address Buffer Connector)
9
Power Fuse
10
Power Connector
5-3-1(C) WAVEFORMS IN NORMAL OPERATION
If the PDP unit and the logic board is in normal operation, the operation LED of Figure 1 would blink at
about 1 second interval.
If the unit is out of order, check the status of the operation LED through eye-inspection first. If the behavior
of the operation LED is different from that of normal state, you have to replace the board. To check trouble
on the board, the following logic board test procedures described below.
❑ 42°" SD s1.0 logic main board T/S
Required test equipment: :
Other equipment: :
Samsung Electronics
Name
Input connector to receive encoded RGB, H, V, DATAEN, and DCLK signal.
It shows Sync and clock are properly received by the logic board.
Connector to connect key scan board to check and adjust 256K data.
256k
EEPROM including gamma table, APC table, drive signal timing and other options
Connector to output Y drive board control signal
Connector to output X drive board control signal
Connector to output address data, and control signal to the E and F buffer boards.
Connector to output address data, and control signal to the E and F buffer boards.
Fuse connected to the power source line of the logic board.
Connector to connect the supply power (5V) with the logic board.
drive board control signal.
- Oscilloscope (digital 400 MHz 3 channel or more)
- Multi meter
- DC power supply (5V: 1EA )
- Sub-PCB ASS'Y for JIG: 1 EA
Circuit Operation Description
Function
5-33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ps42p2sbx/xehPs42p2sbx/xeuPs42pnsbx/xecPs42p2sbxxec

Table of Contents