When The Auto Off Lamp Is Ighted - Panasonic DVCPRO AJ-DE77P Operating Instructions Manual

Non-linear editing system
Hide thumbs Also See for DVCPRO AJ-DE77P:
Table of Contents

Advertisement

<
Error Items
When the AUTO OFF lamp is lighted
STOP _
a
(POWER OFF — ON)
If the capstan motor speed is abnormally low, the AUTO OFF lamp lights.
If an abnormali tension at the supply side is detected in the capstan mode, the} STOP
AUTO OFF lamp lights.
(POWER OFF — ON)
if condensation is detected, the AUTO OFF lamp lights, and the VTR is transferred | EJECT
l
to the eject mode. After the tape is ejected, the drum rotates in order to eliminate
the condensation.
When the condensation has been eliminated, the AUTO OFF lamp go off, and the
VTR can be used.
<Notes>
è If condensation is detected in the eject mode, the drum starts rotating as soon
as it is detected.
e If condensation is detected when the cassette has been inserted, the drum
rotation is stopped, and after the tape is ejected, the drum starts rotating.
if the cylinder motor speed is abnormally high, the AUTO OFF lamp lights.
STOP
(POWER OFF — ON)
If the cylinder motor speed is abnormally low, the AUTO OFF lamp lights. |
STOP
(POWER OFF — ON)
lf the tape start and tape end are detected simultaneously either during or after] STOP
loading, the AUTO OFF lamp lights.
(POWER OFF — ON)
The AUTO OFF lamp lights when the take-up reel has been rotating idly for a fixed| STOP
period of time while the start/end processing operation during loading (half position) | (POWER OFF — ON)
is being performed.
If the cassette does not move up even when 6 seconds have elapsed since the} STOP
VTR was transferred to the eject mode, the AUTO OFF lamp lights.
(POWER OFF — ON)
<Note>
If the cassette does not move down inside the machine even when 6 seconds have
elapsed since the cassette was inserted, the VTR is transferred to the eject mode.
When the unloading operation is not completed within 10 seconds, the AUTO OFF | STOP
lamp lights.
(POWER OFF — ON)
<Note>
When
the loading operation
is not completed within 6 seconds,
the VTR
is
transferred to the eject (unloading) mode.
If the ree! motor at the take-up side is running in the reverse direction, the AUTO | STOP
OFF lamp lights.
(POWER OFF — ON)
lf an abnormal tension at the supply side is detected in the reel mode, the AUTO | STOP
OFF lamp lights.
(POWER OFF — ON)
When the servo microcomputer does not follow the instructions of the system | STOP
control microcomputer even when 10 seconds have elapsed, the AUTO OFF lamp | (POWER OFF — ON)
-29 —

Advertisement

Table of Contents
loading