Sony TRINITRON PVM-14N1A Service Manual page 16

Color video monitor
Hide thumbs Also See for TRINITRON PVM-14N1A:
Table of Contents

Advertisement

14 ineh
3-6. CONVERGENCE ADJUSTMENT
1.
Input a dot pattern signal.
Purity control
CONTRAST ....... Position providing good vision
Purity control
BRIGHTNESS... MIN
2.
Align the horizontal R, G, and B dots at the center of the
screen with the H-STAT VR. (*1)
*1:
If the H-CENTER adjustment was after the H-STAT
adjustment, re-adjust the H-STAT.
(The H-CENT SW changes the H-STAT too.)
3.
Align the R, G, and B at the center of the screen with the
V-STAT magnets. (*2)
*2:
After the V-STAT adjustment, paint on the knobs to lock
them.
<>
A
B
20 inch
x
Purity control
PUY Cone!
Y
Y
Good example
Bad example
V-STAT
magnet
knobs
If the A and B knobs are not
While keeping the angles
symmetrical (I=I'), this has
for A and B equal (I=I'),
bad effects. The focus may de-
align the vertical conver-
teriorate and beam striking
gence.
may occur.
4.
ForHMC, use the 6-pole magnet to adjust the R and B dots to
be symmetrical left and right about the G dot. (*1)
's
1
I
/
A'=
Ss
"
4
»
4
oa
R
G
B
A
A'
Fig. 1
:
A
B
A
A'
—_
-
|
«>
Fig. 2
Fig. 3
Fig. 4
6-pole magnet
The
HMC
adjustment
Adjust the 6-pole magnet so
changes the opening of the
that A=A'. You must maintain
6-pole magnet.
the relationship I=I' while
moving the magnet.
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10