....................15 IGHT CHAPTER 4 HOW TO TURN ON AND TURN OFF THE POWER OF THE TPC- 700/TPC-700P....................16 CHAPTER 5 TPC-700 & TPC-700P’S SETTINGS OPTION ......... 17 CHAPTER 6 BASIC SETUP ................24 6.1 C IP A ..............24...
Page 3
NTERFACE OF THE INGLE 11.2 O VGB-2000 A TPC-700/TPC-700P ..... 63 PERATION TEPS FOR THE PP FOR CHAPTER 12 INTERFACE INTRODUCTION OF THE TPC-700/TPC-700P BUILT-IN DVK-400 APP ....................70 12.1 H ..................... 70 12.2 I ..................72 NPUT UTPUT 12.3 C .....................
Page 5
Datavideo Technologies will try to give correct, complete and suitable information. However, Datavideo Technologies cannot exclude that some information in this manual, from time to time, may not be correct or may be incomplete. This manual may contain typing errors, omissions or incorrect information.
7. This product should only be operated from the type of power source indicated on the marking label of the AC adapter. If you are not sure of the type of power available, consult your Datavideo dealer or your local power company.
Warranty Standard Warranty Datavideo equipment are guaranteed against any manufacturing defects for one year from the date of purchase. The original purchase invoice or other documentary evidence should be supplied at the time of any request for repair under warranty.
Hard Drive, Solid State Drive, SD Card, USB Thumb Drive, Lighting, Camera module, PCIe Card are covered for 1 year. The three-year warranty must be registered on Datavideo's official website or with your local Datavideo office or one of its authorized distributors within 30 days of purchase.
Disposal For EU Customers only - WEEE Marking This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment.
Each button can be customized to your liking. Multi- camera Virtual Studio switching, AUX output, Crosspoint, Flex Source, and PIP assignment can be done by the TPC-700/TPC-700P. Easy to transport to your live production show on the go. Quick connection.
Chapter 3 Connections This chapter will show you the connections of the TPC-700/TPC-700P Touch Panel Controller. For the details of the TPC-700/TPC-700P, please refer to following chapters. 3.1 Front View Interface Description Touch Panel This is the touch panel of the TPC-700/TPC-700P touch...
3.2 Rear View Interface Description Rear Panel This is the rear panel of the TPC-700/TPC- 700P Touch Panel Controller. It provides standard VESA 10cm x 10cm mounting holes.
RJ-45 Ethernet Interface(for RS-232 Control only) This RJ-45 interface is for RS-232 Control only. If users use the TPC-700/TPC-700P to control the SE-3200, it is no need for this interface to connect due to that the TPC-700/TPC-700P adopts the DVIP protocol to control the SE-3200.
Interface Description 12VDC IN interface Please connect a 12V DC power cable to this interface for powering the TPC-700/TPC-700P. RJ-45 Ethernet Interface(For DVIP Control & PoE Only) Please connect one end of an RJ-45 Ethernet cable to this interface and then please connect the other end of this cable to the device that must be controlled by the DVIP protocol.
TPC-700/TPC-700P to turn off the power of the TPC-700/TPC-700P Use the APP: There is a Power-Off button which is located at the bottom side of the TPC-700 APP. Press this button can turn off the power of the TPC-700/TPC-700P.
Chapter 5 TPC-700 & TPC-700P’s Settings Option After you turn on the TPC-700 or the TPC-700P, it will enter the main screen and there is a “Settings” icon which is located at the top-right side of the main screen. After pressing the icon, you can enter the “TPC-700 Setup” interface, the purpose for this “TPC-700 Setup”...
Page 18
Chinese. After that, please press the “Save” button for saving the settings. TPC-700 Network: Please press this key to set various network related parameters including DHCP ON/OFF switch, IP address, Network Mask, Gateway and Primary DNS. The main interface of the “TPC-700 Network”...
Page 19
IP address manually from this section. After the static IP address is entered, please tap the “OK” button for applying Note: Please pay attention that the static IP address of the TPC-700/TPC- 700P must be within the same LAN according to the default static IP...
Page 20
Network Mask: Please press this button for setting the Network Mask manually. The default Network Mask is 255.255.255.0 Gateway: Please press this button for setting the Gateway address manually. Please refer to user manuals of different product models for setting this value in consistent with the default value of each product.
Page 21
MAC Address: This section will show the MAC Address of the TPC- 700/TPC-700P. APP Manage: Press this button allows you to install related Apps for the Datavideo products in the TPC-700/TPC-700P. The main interface of the “App Manage” option is shown in the following diagram. ...
Page 22
Autorun last App ON/OFF toggle switch: If this toggle switch is “ON”, for the next time when the TPC-700 or the TPC-700P is turned on, it will run the app which is operated for the last time automatically.
Page 23
FW Version: This section will show current version number of the “App Manage” software which is installed in the TPC-700 or the TPC-700P. LCD Backlight: This slider allows you to adjust the LCD Backlight brightness with the range of 20%-100%.
Chapter 6 Basic Setup Before using the TPC-700/TPC-700P to control other devices, please make sure that the basic setup of the TPC-700/TPC-700P is done. This chapter will make the SE-3200 HD 12-Channel Digital Video Switcher as an example for explaining how to set the basic setup between the TPC- 700/TPC-700P and the SE-3200.
“Network and Software Setup for Switcher” in the SE-3200 user manual to know the IP address, subnet mask and default gateway of the SE-3200. And then please set the IP address of the TPC-700/TPC-700P to be within the same IP range for further operation.
Page 26
Please follow following steps for operation. 1. After the TPC-700 or the TPC-700P is turned on, please tap the “Settings” icon. 2. Please press the “TPC-700 Network” option.
Page 27
Note: If SE-3200’s IP address is not the default IP address, you need to click the “IP Address” button for setting the SE-3200 and TPC-700/TPC-700P’s IP addresses within the same LAN by using the keypad which is shown in the...
Page 28
4. After going back to the “TPC-700 Network” screen, please press the “Apply” button which is located at the top-right side for applying the settings. 5. After going back to the main interface of the TPC-700/TPC-700P, please tap the SE-3200 App.
Page 29
6. After entering the SE-3200 App, please click the “Setup” and then click the “Connect”button. 7. Please press the “Scan” button to find the connected SE-3200. After that, please select the correct SE-3200 IP address from the drop-down menu and then please press the “Connect” button for connecting the SE-3200 by the TPC-700/TPC-700P.
7.2 Connect by DHCP Please follow following steps for connecting the TPC-700/TPC-700P and the SE- 3200 by the DHCP Mode. 1. After the TPC-700 or the TPC-700P is turned on, please tap the “ Settings” icon. 2. Please tap the “TPC-700 Network” option.
Page 31
3. Please turn “ON” the “DHCP ON/OFF” toggle switch. After that, the TPC-700 or the TPC-700P will obtain the network related parameters including IP address, Network Mask, Gateway AND Primary DNS from the connected router automatically. After all parameters are obtained, please press the “Apply”...
Page 32
“Connect” button. 6. Please click the “Scan” button to find the connected SE-3200. Please select the IP address of the connected SE-3200 from the drop-down menu and then tap the “Connect” button to connect the TPC-700/TPC-700P to the SE-3200.
700/TPC-700P combination allows users to recall the pre-saved 4- camera EFP Chromakey effect virtual scenes easily and rapidly. The default setting for the TPC-700/TPC-700P is that the TPC-700/TPC-700P will recall the No. 101~No. 108 virtual scenes that are pre-saved in the SE-3200.
8.1 The Input Interface Settings for the SE-3200 & TPC- 700/TPC-700P Combination Before recalling the No. 101 to No. 108 user memories’ virtual scenes, users need to know the corresponding relationship between each interface of the SE-3200 rear panel and the elements for each pre- saved virtual scene.
Page 35
SDI IN 2 Please set the Camera 2 in the middle to shoot the close- up for the talent and guests who are sitting in front of the (CH2) green mat. SDI IN 3 The Camera 3 must be set on the right side to shoot the (CH3)...
Page 36
SDI IN 4 The Camera 4 must be set on the left side to shoot the close-up for the guests who are sitting in front of the (CH4) green mat. The built-in virtual scene from the SE-3200(Wide Angle virtual scene) The built-in virtual scene from the SE-3200(The close-up picture is located in the middle)
Please connect a PC to the HDMI IN9 interface of the SE- 3200(CH9)(for playing slides or videos) 8.2 The 8 Pre-saved virtual scenes for the SE-3200 and TPC- 700/TPC-700P Combination User Combination of Final Composite Screen Screen Elements Wide Angle with Full-Body Chromakey with Virtual Scene Background (CH1 Chromakey+CH5...
Page 38
Talent A Close-up Half-Body Talent A Chromakey with Virtual with Background Scene (CH3 Chromakey+CH7 Virtual Scene) Talent B Close-up Talent B Chromakey with Virtual Scene with Background (CH4 Chromakey +CH8 Virtual Scene) Talent A+PC Source Talent A Half-Body + Content (CH3 Chromakey+CH9 Background)...
Page 39
Talent B+ PC Source Talent B Half-Body +Content (CH4 Chromakey+CH9 Background) Talent A Close-up Talent A Half-Body Chromakey with Virtual with Background+ PC Scene+ Content Source)(CH3 Chromakey +CH7 Background+CH9 PIP) Talent B Close-up Talent B Half-Body Chromakey with Virtual with Background +PC Scene+ Content Source(CH4 Chromakey+CH8...
It is necessary to use the Chromakey and Still related functions of the SE-3200 for controlling the SE-3200 and for recalling the pre-saved virtual scenes directly by the TPC-700/TPC-700P. For the setting details and the operating steps, please refer to the 4.2 Keyer, 4.3 Chroma, 4.4 P-In-P and the Still related paragraphs of the 4.9 Files from the SE-...
“Virtual Studio”, “AUX”, “Cross Point”, “Flex Source”, “PIP” and “Setup” options for users to control the SE-3200 remotely by the TPC-700/TPC-700P and an RJ-45 Ethernet cable. The main interface of the built-in SE-3200 control App for the TPC-700/TPC-700P is shown as following diagram.
10.1 Virtual Scenes The Virtual Studio option allows users to recall the pre-saved No. 101 to No. 108 User Mems settings in the SE-3200 by the TPC-700/TPC- 700P. There are 8 virtual scenes can be used by users including “Wide Angle with background”, “Close-up with background”, “Talent A close-...
Page 43
2. Close-up with background 3. Talent A close-up with background...
Page 44
4. Talent B close-up with background 5. Talent A + PC Source...
Page 45
6. Talent B + PC Source 7. Talent A close-up with background + PC Source.
1. Please make sure that all of the 8 virtual scenes are saved into the No. 101 to No.108 User Mems in advance. Moreover, please make sure that the SE- 3200 main unit, the control panel, the TPC-700/TPC-700P and the router are connected correctly.
10.2 AUX The Datavideo TPC-700/TPC-700P with the SE-3200 control software allows users to use the “AUX” function. The “AUX” function allows users to assign signal sources including CH1 to CH-12 input sources, PGM, PVW, CLN PGM, CLN PVW, PG + DSK, MULTIV, MULTIV2, STILL1, STILL2, FLEX SRC and FLEX SRC2 randomly to the output interfaces such as SDI1, SDI2, SDI3, SDI4, SDI5, SDI5, SDI6, HDMI1, HDMI2 and HDMI3 to be the output sources.
Page 48
2. Please select your desired signal source for output from the “SELECT” area. 3. Users can finish the signal assigning for the AUX function.
10.3 Cross Point The “Cross Point” option allows users to adjust the sequence of the input signals by themselves without changing any input cables. For example, users can assign the signal source which is originally connected to input 2 to be the signal source of input 1.
Page 50
Note:If you want to turn off the output of the “VIDEO XPT” area, please tap the “OFF” button. If you want to use the embedded audio of the output video as the output audio source, please tap the “Follow” button. ...
Page 51
2. Users can enter the “PGM AUDIO SETTING” interface to adjust the audio Gain and audio Delay. How to Use the “PGM AUDIO SETTING” Interface...
1. Please tap the No.1 arrow to decrease the Audio Gain and Audio Delay. 2. Please tap the No. 2 arrow to increase the Audio Gain and Audio Delay. 3. Please tap the No. 3 slider to increase or decrease the Audio Gain and Audio Delay by dragging the No.3 slider forward or backward.
10.4.1 How to Use the Flex Source Function Please follow following steps for using the Flex Source function. How to Set the Background Picture for the Flex Source 1. At first, please tap the “Src Bgnd” button which is located at the “FLEX 1” area to select the background function for the Flex Source.
Page 54
2. Please tap the source signal channel that you want to use to be the Src background picture from the “SELECT” area. (The source signal channels include BLK, 1~12, STILL 1 & STILL 2, MATTE and BARS). How to Set the Sub-Picture Source Signal for the P-In-P of Flex Source 1.
Flex 1 : Flex 2 : Bgnd x 1, PIP x 3 Different Bgnd x 1, PIP x 1 Flex 1 : Flex 2 : Bgnd x 1, PIP x 4 Different Bgnd x 1, PIP x 0 Users can know from the above-mentioned examples that the FLEX 1 mode and the FLEX 2 mode can display different Bgnd background screen respectively.
Page 56
How to Set the Sub-Picture Source Signal for the PIP 1. At first, please tap the “Src 1”, “Src 2”, “Src 3” or “Src 4” button from the PIP area. 2. Please tap the source signal channel that you want to use to be the Src 1, Src 2, Src 3 or Src 4 sub-signal from the “SOURCE”...
10.6 Setup The built-in SE-3200 control interface of the TPC-700/TPC-700P allows users to set many parameters including Language, Connect, Screen Saver, FW Version and Model. The main interface for the Setup is shown as the following diagram. 1. Language: This button allows users to select three different language interfaces including Traditional Chinese, English and Simplified Chinese.
Page 58
After that, please click the “Connect” button to connect the TPC- 700/TPC-700P and the SE-3200. If the “Disconnect” button is pressed during the TPC-700/TPC-700P and the SE-3200 are connected, the connection will be cancelled. If the “Cancel” button is pressed, it will go...
Page 59
3. Screen Saver: Please press this button to enter the “Screen Saver” main interface which allows you to adjust the screen saver wait time within 0(OFF) to 10 minutes range by using a slider. After the adjustment is finished, please click the “Save”...
Page 60
5. Model: This column will show the product model which is connected by this App, which is the SE-3200. 6. Quit App: Please press this button to quit the SE-3200 App and then go back to the main screen of the TPC-700/TPC-700P.
Chapter 11. Introduction of the Built-in VGB-2000 App Interface for the TPC-700/TPC-700P When the User Memory of the SE-1200MU is set, users can use the TPC-700 Touch Panel Controller to apply their needed default mode directly. 11.1 Main Interface of the TPC-700 App-Single & Dual Please see following diagram for the Single &...
Page 62
Chromakey” and “Wide Angle with Chromakey + Interactive Pen Mark”. Moreover, you can choose Traditional Chinese, Simplified Chinese or English from the language drop-down menu . Click the button allows you to quit the VGB-2000 App and then go back to the main interface of the TPC-700/TPC-700P.
RS-232 interface which is on the rear panel of the VGB-2000 to the RJ-45 interface of the TPC-700. Step 2. After the preset settings of the SE-1200MU are set, users can apply their desired effects by tapping the option which is shown on the TPC-700 screen directly. ...
Page 64
Close Up + Interactive Pen Mark + Logo Interactive Pen Mark + Logo...
Page 65
Interactive Pen Mark Close Up with Chromakey + Slides...
Page 66
Dual Camera Effects Close Up + Interactive Pen Mark Close Up + Interactive Pen Mark + Logo...
Page 67
Interactive Pen Mark + Logo Interactive Pen Mark...
Page 68
Close Up with Chromakey Wide Angle with Chromakey...
“Input/Output”, Chromakey”, “Lumakey” “Window”, “User Memory”, “Connect” and “Setup” options for users to control the DVK-400 remotely by using the TPC-700/TPC-700P and the RJ-45 Ethernet cable connection. The main interface of the TPC-700/TPC-700P built-in DVK-400 app is shown in the following diagram. 12.1 Home After related parameters in the DVK-400 PC App are set in advance, the “Home”...
Page 71
Lumakey ON/OFF: Press this button allows you to switch between the “Lumakey ON”and “Lumakey OFF”. Lumakey ON: This allows you to apply the Lumakey effect. Lumakey OFF: If this button is pressed, the Lumakey effect will not be applied.
If the “BG Blur ON” is set, it will turn on the BG Blur function. If the “BG Blur OFF” is set, it will turn off the BG Blur function. 12.2 Input/Output After related parameters in the DVK-400 PC App are set in advance, the Input/Output option allows you to select the foreground input source and the output or preview screen type.
The output image sources are shown in the following diagram. FG: The input source of the foreground camera. BG: The input source of the background camera. Matte: Mask. PFG: Processed Foreground Image. Comp: Composite image for foreground and background images ...
Chromakey ON/OFF:Click this toggle switch to turn on or turn off the Chromakey function. Black Level: The Black Level value can be adjusted directly by using this slider. The default value of the Black Level is 200. If this value is increased, black objects or hair will be more obvious.
Page 75
Lumakey ON/OFF toggle switch:Click this toggle switch to turn on or turn off the Lumakey function. KEY MODE: There are two Modes including Black and White Modes. Click this button once to switch between the Black and White. Select “Black”...
12.5 Window After related parameters in the DVK-400 PC App are set in advance, the Window option allows you to turn on or turn off the “Garbage Window” and “Holdout Window” ON/OFF buttons. Moreover, it also allows you to adjust the “Top”, “Bottom”, ”Left”...
12.6 USER MEMORY After related parameters in the DVK-400 PC App are set in advance, the User Memory option allows you to save or load up to 8 setting values. How to save the User Memory setting: At first, please make sure that your desired settings are set in the DVK-400 PC App in advance.
DVK-400 which is connected by the TPC- 700/TPC-700P automatically. Select Device:This option will show the IP address of the connected DVK-400. Connect:When the interface is selected and the DVK-400 is found, please click this “Connect” button to connect the TPC-700/TPC-700P with the DVK- 400.
12.8 Setup After related parameters in the DVK-400 PC App are set in advance, the “Setup” option allows you to set various parameters including “Output Resolution”, “HDMI Output Format”, “Language”, “FW Version”, “FPGA Version”, “Bootloader Version” and “Screen Saver”. The main interface of the “Setup”...
Page 80
Output Resolution:Please press this button to select your desired output resolution. After that, please press the “Save” button to select your desired DVK-400 output resolution. HDMI Output Format:Please press this button to select your desired HDMI output format from the three output formats which are shown in the following diagram.
Page 81
Bootloader Version:This column will show the Bootloader Version. Note:The FW Version, FPGA Version and Bootloader Version will be shown only when the TPC-700 or the TPC-700P is connected to the DVK-400 successfully. Factory Default:After the “Factory Default” button is pressed, the Factory Default confirmation dialogue box will be shown.
Page 83
Quit APP:After the “Quit APP” button is pressed, the “Quit APP” dialogue box will be shown. After the “OK” button is pressed, the DVK- 400 App will be closed.
Page 84
Screen Saver: After entering the “Setup” page, please press the “right arrow” button to show the “Screen Saver” option which is shown in the following diagram. After pressing the “Screen Saver” button, you can see the “Screen Saver” adjustment slider for you to adjust the “Screen Saver” wait time from 0(OFF) to 10 minutes which is shown in the following diagram.
Switcher web UI functions within one app. Moreover, the ZR-1 app allows you to control up to 3 cameras at the same time. Before controlling the Datavideo iCAST 10 NDI, what you need to do is to finish the connections and settings for all facilities.
After the connection is done, please make sure that your iCAST 10 NDI, PTZ cameras and TPC-700 or TPC-700P are set in the same IP range for controlling your iCAST 10 NDI by the TPC-700 or TPC-700P. In the following section, we will introduce the user interface of the ZR-1 app for you.
Page 87
4. The ZR-1 app will search the connected DVIP devices. 5. After the connected devices are found, the main interface will be shown. You can tap the button which is located at the top-right side of the screen to select “2 cams” or “3 cams” main interface.
13.2.1 3 cams Interface-Home 1. CAM A:The “CAM A” button allows you to show the image source which is shot by the camera connected to the HDMI input 1 of the iCAST 10 NDI to the PGM external monitor. 2. CAM B: The “CAM B” button allows you to show the image source which is shot by the camera connected to the HDMI input 2 of the iCAST 10 NDI to the PGM external monitor.
Page 89
8. Stream: Once the video encoding and streaming related parameters are set in the “EncodingEncoder” and “EncodingStream” in advance, you can press this “Stream” button to stream up to 12 video sources including CH1, CH2, CH3, CH4, CH5 and PGM for the Main and Sub encoders to different live- streaming platforms simultaneously.
Page 90
Before using this function, you have to make sure that your account and password are set in advance in “Account & PasswordAdd New User”. You can press the gear icon which is located on the top-right side of the screen to enter the “settings”...
Page 91
B: Account & Password: Please press this button to change the administration password, to add a new user, to reset the user password and to delete the unwanted users. The main interface of the “Account & Password” is shown in the following diagram.
Page 92
this button and then press the user name which should be deleted. After that, please press the “Apply” button. You will see a reminder, please press the “Delete” button to delete the selected user. C: Factory Default: This button allows you to reset the app to its factory default value.
Tracking function when Datavideo AI Auto Tracking cameras are connected to the iCAST 10 NDI. You can connect up to 4 Datavideo AI Auto Tracking cameras to the HDMI input interfaces on the rear panel of the iCAST 10 NDI. Once the ZR-1 app detects that the connected cameras are not AI-enabled, those four buttons will be shown in white.
Page 94
“5. Document Camera” in 13.2.1 3 cams Interface-Home for details. 5. PIP A: The PIP A button of the “2 cams” mode is the same as the PIP A button in “3 cams” mode. Please refer to “6. PIP A” in 13.2.1 3 cams Interface- Home for details.
Auto-Tracking On/Off buttons of the “2 cams” mode are the same as the Auto-Tracking On/Off buttons of the “3 cams” mode Please refer to “14. AI Auto-Tracking On/Off buttons for CAM A/CAM B/CAM C/CAM D” in 13.2.1 3 cams Interface-Home for details.
Page 96
4. Network: This option allows you to see the IP address of the connected devices. You can also press the “Network” button of each connected device to modify the network settings. 5. Add Device: If the connected devices can not be found by the automatic scanning, please press “Add DeviceScan in Network”...
8. Save: This button allows you to save a device list for further use. When all devices are connected and shown successfully, press this button to save the device list. 9. The left and right arrow buttons: These two buttons allow you to switch between the first and the second pages of the device list.
Page 98
You can tap each option including “Resolution”, “Profile”, “Entropy”, “Video(bps)”, “Frame Rate” and Level to set your desired value. After that, please press the “Save” button in each page. After all of the parameters are set, please press the “Apply” button. Press the “Reset” button to reset it to factory default value.
Page 99
3. Entropy: You can select “CAVLC” or “CABAC” from the “Entropy” page which is shown in the following diagram. 4. Video (bps): This option allows you to select your desired video Bitrate.
Page 100
5. Frame Rate: This option allows you to select your desired frame rate for the main or sub encoder. 6. Level: The “Level” option is fixed at “High 4.2” and can not be adjusted by users. 7. “Record” icon: You can press this icon to switch to the “Recorder”...
Page 101
Record 1. Encoder Source: This option allows you to select “Main Encoder” or “Sub Encoder” as the encoder source. Moreover, this option can be disabled.
Page 102
2. File Name: This option allows you to set the file name of the recorded file. Please enter your desired file name and then press the “OK” button. 3. Type: This option allows you to set the file type for the recorded file. 4.
Page 103
5. Storage Capacity: This option allows you to set the “Format Type” of the storage media. Moreover, this option allows you to see the “Device Name”, “Available Capacity” and “Used Capacity”. 6. “Encoder” icon & “Stream” icon: You can press the “Encoder” icon switch to the “Encoder”...
Page 104
Stream 1. Encoder Source: This option allows you to set the encoder source for streaming.
Page 105
2. Stream Type: This option provides you many stream types including RTSP, RTMP, TS, HLS, NDI and SRT for you to select. 3. RTSP Port: The default port number is 554 or you can tap this option to modify the port number. 4.
Page 106
5. Account: This option provides you the “Account” of the streaming, the default value is “root” or you can tap this option to modify the password. . 6. Password: This option provides you the “Password” of the streaming, the default value is “root” or you can tap this option to modify the password. 7.
8. “Encoder” icon & “Record” icon: You can press the “Encoder” icon switch to the “Encoder” page. You can press the “Record” icon to switch to the “Record” page. 13.2.5 Camera-for 3 cams & 2 cams Interfaces The “Camera” option allows you to set the camera related parameters including “White Balance”, “FOCUS”, “IRIS”, “ZOOM IN”...
Page 108
2. FOCUS: This section allows you to apply the Auto FOCUS setting or to adjust the FOCUS manually. AUTO: Press this button to apply the Auto FOCUS. MANUAL: Once the “MANUAL” button is pressed, you can adjust the “FOCUS”...
How to Recall a Preset Position After the preset position is presaved, please press the “CAM A”, “CAM B”, “CAM C” or “CAM D” button in the “CAMERA” section. After that, please press the 1, 2, 3 or 4 button from the “POSITION” section to recall your preset position.
Page 110
4. POP: Once the “POP” button is pressed, you can select you desired input sources from the input 1 to input 5 to combine with your POP PGM screen by pressing buttons on the “PGM SOURCE” section. 5. Side By Side: Once this button is pressed, the selected two input sources from the “PGM SOURCE”...
Page 111
7. PIP 2: Once the “PIP 2” button is pressed, you can select one input from the button 1 to button 5 on the right side of the “PGM SOURCE” section to be the main PGM screen and then you can also select another input from the button 1 to button 5 on the left side of the “PGM SOURCE”...
Page 112
9. PIP 4: Once the “PIP 4” button is pressed, you can select one input from the button 1 to button 5 on the right side of the “PGM SOURCE” section to be the main PGM screen and then you can also select another input from the button 1 to button 5 on the left side of the “PGM SOURCE”...
Page 113
“Height” of the “PIP 5 Window” can be adjusted by the “PIP 5 Window Editor”. 11. PIP 5 Window Editor: Please press the “Edit” button below the PIP5 to enter the PIP 5 Window Editor. The main interface of the PIP 5 Window Editor is shown in the following diagram.
Page 114
D: Back: Press this button to go back to the previous page. ii & iii: Pst X & Pst Y: These “Pst X” and “Pst Y” buttons allow you to determine the X & Y coordinates of the PIP 5 window within the whole screen. Please press the “Pst X”...
Page 115
viii. PIP 5 Window Frame: This window frame presents the position which the PIP 5 window will appear on the external screen (the black section) and you can touch any point of the black section by your finger to change the position of the PIP 5 window frame directly.
PGM screen. 13.2.7 Audio-for 3 cams & 2 cams Interfaces The “Audio” tab allows you to adjust the volume and delay for all audio channels. There are two pages for the “Audio” tab. The main interface for the “Audio” tab is shown in the following diagram. The above-mentioned interface allows you to adjust the audio volume and delay for all audio channels by using sliders.
Page 117
For AUX 1 and AUX 2, you can select different audio sources from “IP Stream/NDI 1”, “IP Stream NDI 2”, “IP Stream NDI 3”, “Web RTC” or “Audio Over IP”. Please press the “Source Select” button to enter the “Source Select” page.
TVS-2000A PC version shortcut keys in advance. After that, you can use the TPC-700/TPC-700P built-in TVS-2000A app to control your TVS- 2000A PC version. For the setup of the TPC-700/TPC-700P & TVS-2000A and the way to set the TVS-2000A PC version shortcut keys, please refer to “DownloadsOthers”...
Page 119
Button 2 is corresponding to the shortcut key “F2” in the TVS-2000A PC version software. 3. Button 3: The Button 3 allows you to show the near view of the right side camera angle to the PGM screen of the TVS-2000A. The Button 3 is corresponding to the shortcut key “F3”...
Page 120
Language: The “Language” button allows you to choose your desired language for displaying the user interface of the TVS- 2000A app. Please press this button to choose your desired display language for the TVS-2000A app. The English user interface is ready now, however, the traditional Chinese and simplified Chinese user interfaces will be available in the near future.
Page 121
Please follow the following steps to replace the thumbnail for the Studio A, B, C or D. 1. At first, please make sure that the TVS-2000A and TPC-700 are connected successfully. 2. Please press the TVS-2000A app icon to open the TVS-2000A app.
Page 122
5. You can see the “Studio Image” interface. We will take Studio A as an example. Please press the “Edit” button. 6. You can see the default Studio A thumbnail, which is the thumbnail...
Page 123
7. If you want to exchange the thumbnail between Studio A and Studio B, please enter the Setup page and then press “Studio ImageStudio A Edit to select the thumbnail 03. And then press the “Apply” button.
Page 124
8. After that, please press “Studio ImageStudio B Edit” to select the thumbnail 02. And then press the “Apply” button.
Page 125
9. Finally, you can see that the thumbnails of the Studio A and Studio B are successfully exchanged. Screen Saver: This Screen Saver option allows you to set the wait time for activating the screensaver. Please press the “Screen Saver”...
14.2 Advance 1. Button 1: The Button 1 for the “Advance” tab is the same as the Button 1 in the “Home” tab. Please refer to 14.1 Home 2. Button 2: The Button 2 for the “Advance” tab is the same as the Button 2 in the “Home”...
Page 127
Button 7 is shown in white, it means that the video recording is not activated or is stopped. Video Recording is in progress No Video Recording. 8. Button 8: The Button 8 is corresponding to the “STREAM” button of the TVS-2000A PC version, it allows you to start and stop a video live streaming for the “Program”...
14.3 Studio 1. Studio A: The “Studio A” button allows you to recall the presaved Studio A virtualset in the TVS-2000A PC version by pressing the Studio A button only. The Studio A button corresponds to the F7 shortcut key in the TVS-2000A PC version.
Page 129
5. Gear Icon: Please press the gear icon to enter the “Setup” page. This option is the same as the gear icon in “Home” and “Advance” pages. Please refer to 14.1 Home for details.
3. There is a folder with the latest software update files which the folder name is “datavideo” after the software is unzipped. 4. Please copy the whole “datavideo” folder to the root directory of your USB thumb drive. 5. Please insert your USB thumb drive with the latest TPC-700/TPC-700P software into the USB port which is located at the left side of the TPC- 700/TPC-700P.
Page 131
Note: After the software update is finished, there is a file which the file name is “done” will be generated automatically by the TPC-700/TPC-700P system and will be saved in your USB thumb drive. If users want to update the same version of the software for the next time, please remember to delete that “done”...
Chapter 17. Specifications TPC-700/TPC-700P Specifications Touch Screen 7” capacitive touch screen Touch Screen 800 x 480 Resolution Software Upgrade via USB 2.0 interface Control Protocol via RS-232(RJ-45 interface) Power DC 12V 802.3af(For TPC-700P Only) Power Consumption 220 x 152 x 79 (mm)
1. For the TPC-700/TPC-700P App Manage Software, there is one zip file with the file name: tpc700_v2.0.15_20210714.zip 2. For the TPC-700/TPC-700P App for each product model, there is one zip file with the file name (take SE-3200 as an example): datavideo_se3200_v2.2.10.7zip...
2.2 Software Update Preparation The following items are required to perform this Software update. Please prepare these items in advance before performing the update. The TPC-700 or the TPC-700P is TPC-700 or TPC-700Px 1 needed for updating the Software. USB 2.0 or USB 3.0 USB Flash Drive x...
2.3 System Connection Diagram TPC-700 Power Flash Drive...
Page 137
TPC-700P Powered by an Ethernet Cable or a 12V DC IN Cable Flash Drive Note: Only the TPC-700P supports the “PoE” function. If the power is supplied by the Ethernet cable, please DO NOT use the DC IN power cable as the power source.
The Software version for the “App Manage” software. 2.4.1. Please connect a DC 12V power adapter. Please connect a DC 12V power adapter to the TPC-700 or the TPC-700P. 2.4.2 Please turn on the power. Please turn on the power of the TPC-700 or the TPC-700P.
Page 139
The current version for the App for different product models. 2.4.5. Please connect a DC 12V power adapter. Please connect a DC 12V power adapter to the TPC-700 or the TPC-700P. 2.4.6 Please turn on the power. Please turn on the power of the TPC-700 or the TPC-700P.
Page 140
2.4.8 If the TPC-700 or the TPC-700P is not connected to the assigned product model, the following two dialogue boxes will be shown. If the TPC-700 or the TPC-700P is not connected to the assigned product model, the following two dialogue boxes will be shown. Please tap the “Setup”...
Page 141
2.4.9 You can see the current app version of the selected model. The current app version of the selected model will be shown in the following diagram.
The file name for the TPC-700/TPC-700P App for the specific product model (take SE-3200 as an example) is “datavideo_se3200_v2.2.10.zip” Please unzip the downloaded Software files into the hard disk of your laptop and then you can see the following file folders for the TPC-700 or the TPC- 700P. ...
Page 143
Please insert the USB flash drive to the USB interface of the TPC- 700/TPC-700P. 3.1.3. Please turn on the power of the TPC-700/TPC-700P. Please turn on the power of the TPC-700/TPC-700P, the following screen will be shown and the software update procedure of the “App Manage” software will be started.
Page 144
3.1.4. After the software update procedure is finished, the following screen will be shown. After the software update procedure is finished, the following screen will be shown. Please tap the “Settings” icon to enter the “TPC-700 Setup” page. 3.1.5. You can see the updated software version number.
Page 145
USB flash drive. 3.1.7. Please insert the USB flash drive to the USB interface. Please insert the USB flash drive to the USB interface of the TPC-700/TPC- 700P. 3.1.8. Please turn on the power of the TPC-700/TPC-700P.
Page 146
Remove the old version App 3.1.9. Please tap the “Settings” icon. Please tap the “Settings” icon from the initial screen.
Page 147
3.1.10. Please tap the “App Manage” option. Please tap the “App Manage” option from the “TPC-700 Setup” page. 3.1.11. You can see all of the apps for different product models. You can see all of the apps for different product models which are...
Page 148
3.1.12. Please tap the “Uninstall” button. Please tap the “Uninstall” button for the product model which is needed to be uninstalled (Take SE-3200 as an example). 3.1.13. The “Uninstall” confirmation dialogue box will appear. The “Uninstall” confirmation dialogue box will appear, please press the “OK”...
Page 149
3.1.16. Please insert your USB flash drive into the USB interface. Please insert your USB flash drive into the USB interface of the TPC- 700/TPC-700P. 3.1.17. Please turn on the power of the TPC-700/TPC-700P and then the initial screen will be shown as the following diagram.
Page 150
Please turn on the power of the TPC-700/TPC-700P and then the initial screen will be shown as the following diagram. 3.1.18. Please tap the “Settings” icon to enter the TPC-700 Setup page.
Page 151
3.1.19. After entering into the TPC-700 Setup page, please tap the “APP Manage” option. After entering into the TPC-700 Setup page, please tap the “APP Manage” option which is shown as the following diagram. 3.1.20. Please click the “Install” button for installing new version app.