KTI Networks KPOE-200 Installation Manual

Industrial high-power single-port c++ mid-span c

Advertisement

Quick Links

KPOE-200
Industrial High-Power Single-Port
PoE++ Mid-span Injector
Installation Guide
DOC.180529A
-1-

Advertisement

Table of Contents
loading

Summary of Contents for KTI Networks KPOE-200

  • Page 1 KPOE-200 Industrial High-Power Single-Port PoE++ Mid-span Injector Installation Guide DOC.180529A...
  • Page 2 (C) 2018 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced in any form or by any means or used to make any directive work (such as translation or transformation) without permission from KTI Networks Inc.
  • Page 3 The information contained in this document is subject to change without prior notice. Copyright (C) All Rights Reserved. TRADEMARKS Ethernet is a registered trademark of Xerox Corp. FCC NOTICE This device complies with Part 15 subpart B Class A of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including the interference that may cause undesired operation.
  • Page 4: Table Of Contents

    Table of Contents 1. Introduction ........................... 5 1.1 Features ......................5 1.2 Product Panels ....................6 1.3 LED Indicators ..................... 6 1.4 Specifications ...................... 7 2. Installation ........................... 11 2.1 Safety Cautions ....................11 2.2 Mounting the Device to a Wall ................12 2.3 Mounting the Device to a DIN-Rail ..............
  • Page 5: Introduction

    1. Introduction Power over Ethernet provides a way for Ethernet network devices to be powered by UTP cables, including Cat.5, 5e, and 6 rather than by separate power cords. The device is a mid-span injector that can deliver output power supporting proprietary PoE++ 90W Type 4 PDs, 802.3at Type 2 high-power PDs, and 802.3af Type 1 PDs.
  • Page 6: Product Panels

    1.2 Product Panels The following figure illustrates the components of the device: 1.3 LED Indicators Function DC IN DC power input status PoE output power status...
  • Page 7: Specifications

    1.4 Specifications DATA IN Jack Connector Shielded RJ-45 jack Connection support IEEE 802.3 10Base-T, IEEE 802.3u 100Base-TX, IEEE 802.3ab 1000Base-T Network cable Cat.5, 5e, 6 UTP or better Pin assignments 10/100Base-TX & 1000Base-T connections 10/100Base-TX 1000Base-T BI_DA+ BI_DA- BI_DB+ BI_DC+ BI_DC- BI_DB- BI_DD+...
  • Page 8 DC Power Terminal Block Connector Flange terminal block 3P Contacts DC Isolated to chassis ground Marking Remark DC power input (+) DC power input (-) Protective earth (Connected to chassis ground inside) DC Power Jack Ø Ø Connector DC Jack (- 6.3mm/+ 2.0mm) for external AC-DC power adapter Contacts...
  • Page 9 PoE PD classes support PSE output vs. PD input Type Class DC power min. * PSE output PD input min. * 15.4W 12.95W 3.84W 6.49W 15.4W 12.95W 25.5W 38.7W 52.7W 128W *1: The associated classes are proprietary std. *2: The minimum DC power voltage to support the specified PSE output *3: The minimum power received at the PD end in worst case Mechanical Dimension (base)
  • Page 10 IEC 61000-4-8 IEC 61000-4-11 IEC60950-1 (EN 60950-1 LVD) Safety IEC 60068-2-64 Vibration IEC 60068-2-27 Shock test NEMA TS2 environment -10-...
  • Page 11: Installation

    2. Installation 2.1 Safety Cautions To reduce the risk of bodily injury, electrical shock, fire and damage to the product, observe the following precautions: Do not service any product except as explained in your system documentation. Opening or removing covers may expose you to electrical shock. Only a trained service technician should service components inside these compartments.
  • Page 12: Mounting The Device To A Wall

    2.2 Mounting the Device to a Wall The back panel of the device is featured a wall mount hole as follows: 2.3 Mounting the Device to a DIN-Rail In the product package, a DIN-rail bracket is provided or has been installed for mounting the device in a industrial DIN-rail enclosure.
  • Page 13 2. Attach bracket to the lower edge of the DIN rail and push the unit upward a little bit until the bracket can clamp on the upper edge of the DIN rail. 3. Clamp the unit to the DIN rail and make sure it is mounted securely. The final dimension is: -13-...
  • Page 14: Mounting The Device On A Panel

    2.3 Mounting the Device on a Panel The device may be provided optionally with a panel mounting bracket. The bracket supports mounting the device on a plane surface securely. The mounting steps are: 1. Install the mounting bracket on the device. 2.
  • Page 15 The final dimension is: -15-...
  • Page 16: Applying Dc Power

    2.4 Applying DC Power DC Power Connectors The device is featured with three different DC power input connectors for supporting different types of external AC-DC power supply or AC-DC power adapters. Connector Marking Power Supply Terminal Block General DC power supply with terminal contacts DC Jack AC-DC power adapters with DC plug Female Power DIN...
  • Page 17 DC power input vs. PoE power output Type PD Class max. Working V dc_in +45 ~ 57V 0.375A +45 ~ 57V 0.112A +45 ~ 57V 0.208A +45 ~ 57V 0.375A +45 ~ 57V 0.636A +45 ~ 57V 0.919A +45 ~ 57V 1.35A +45 ~ 57V 1.65A...
  • Page 18: Power Loss

    2.4.1 Power Loss The power voltage received at the PD end over Cat.5 is different from the voltage supplied at the device’s DC power connector. The voltage drop is caused by the resistance inside the device and the Cat.5 LAN cable line resistance before the power arrives PD end.
  • Page 19: Making Lan Connections

    3. Making LAN Connections 3.1 Data In Jack The RJ-45 jack is used to connect a PoE-incapable Ethernet device that communicates with the remote powered device. The injector operates transparently to Ethernet port functions like auto MDI/MDI-X function and Auto-negotiation function. The network signal is forwarded to PoE OUT jack. It supports: Ethernet interfaces 10BASE-T, 100BASE-TX, 1000BASE-T...
  • Page 20: Connection Distance

    3.3 Connection Distance Connecting standard PD The following figure illustrates a typical application of the device connecting to a standard PD. The cable distance including the segment from the injector to the Ethernet device and the segment to PD is no more than 100 meters.
  • Page 21: Led Indication

    3.4 LED Indication State Interpretation No power is supplied on DC power input. DC IN DC power is supplied. PoE output is shutdown. PoE power is delivered. -21-...
  • Page 22: Supporting Products

    4. Supporting Products Power Supplies PA-48V-0.75A/U AC-DC power adapter with 48V 36W output for USA PA-48V-0.75A/E AC-DC power adapter with 48V 36W output for Europe L02-0001-031 AC-DC power adapter with 48V 90W output KPW-300T-48 AC-DC Power supply for PoE/PoE+ with DC48V output up to 300W KPW-300T-52 AC-DC Power supply for PoE/PoE+ with DC52V output up to 300W KPW-300T-54...

Table of Contents