Western Digital OpenFlex Data24 3200 User Manual page 172

Table of Contents

Advertisement

User Guide
rdma_pkey: 0x0000
Step 3 :
Connect to the device using the subnqn.
sudo nvme connect -t rdma -i 16 -a 192.168.10.51 -n
nqn.1992-05.com.wdc.openflex-data24-3200-usalp00000aa000a:nvme.1
Verify the connection using
Step 4 :
root:~$ sudo nvme list -v
NVM Express Subsystems
Subsystem
------------ -------------------------------------------------
----------------
nvme-subsys0 nqn.1992-05.com.wdc.openflex-data24-3200-usalp00000aa000a:nvme.1
NVM Express Controllers
Device
Address
-------- -------------------- ----------------------------- -------- ------
-------------- ------------ ----------------
nvme0
traddr=192.168.10.51 trsvcid=4420 nvme-subsys0 nvme0n1
NVM Express Namespaces
Device
------------ -------- -------------------------- ----------------
----------------
nvme0n1
  R esult:   T he connection to the NVMe devices on the OpenFlex Data24 3200 have been made.
Note:
This example calls out the IOM-A and AIC-A with the result AA,
bolded above. The example also calls out the device number with the
numeral 1 at the end of the string, bolded in the following example: subnqn:
nqn.1992-05.com.wdc.openflex-data24-3200-usalp00000aa000a:nvme. 1 . The 1
indicates the device (SSD) system slot number.
nvme list -v
Subsystem-NQN
SN
Subsystem
Namespaces
AXXXXXXX
NSID
Usage
1
3.84
.
nvme0
MN
WUSxxxxxxx
Format
TB /
3.84
TB
512
4. Management
4.6 NVMe-CLI
Controllers
FR
TxPort
R2109003 rdma
Controllers
B +
0 B
nvme0
164