Download Print this page

Installation Instructions - American Standard loT Detectlnk Paradigm 702B405 Owner's Manual

Integrated faucet with optional above-deck mixing & smartherm

Advertisement

INSTALLATION INSTRUCTIONS

1
SPOUT ASSEMBLY INSTALLATION
Turn off hot and cold water
supplies before beginning.
1. Make sure O-RING (1) is installed in spout base.
IMPORTANT: Do not use putty when installing faucet
without escutcheon.
2. If installing DECK PLATE (2) (optional): Apply a bead of
putty to bottom edge of PUTTY PLATE (2). Install SCREW
(11) into the MOUNTING BASE OF THE FAUCET (13) and
allign SCREW (11) with HOLE (12).
3. Insert supply HOSES (3), SHANK (4) and WIRES (5)
through hole in DECK PLATE with PUTTY PLATE (2) and
mounting surface.
4. Assemble RUBBER WASHER (7), BRASS WASHER (8)
and THREADED LOCKNUT (9) onto SHANK (4) from
underside of sink or mounting surface. Hand tighten
LOCKNUT (9).
5. Use a screwdriver to tighten SCREWS (10) on LOCKNUT
(9). Work your way around LOCKNUT (9), tightening the
screws slightly each time until all are snug to ensure even
pressure.
A
2
MAKE WATER SUPPLY CONNECTIONS
1. Turn off hot and cold water supplies before beginning.
2. Install FLOW SENSOR (3) on each wall supply outlet. Be sure
that FLOW SENSOR (3) is inserted in the correct direction.
3. Connect HOT FLEXIBLE SUPPLY (marked with red stripe) (1)
to FLOW SENSOR (3) on hot water control stop (4). Connect
COLD FLEXIBLE SUPPLY (marked with blue stripe) (2) to
FLOW SENSOR (3) on cold water control stop (5). Use
adjustable wrench to tighten connections. Do not over tighten.
4. Faucet supplies are 24" long from faucet base.
Note: If additional supply length is required, installer
must purchase those parts separately.
Important; If SUPPLY HOSES (1, 2) are too long, loop
as illustrated to avoid kinking.
Note: For non-mixing models only one flow sensor and
supply line connection is needed.
B
use putty when installing
faucet without escutcheon.
13
11
12
5
3
7
8
9
1
3
(3) FLOW
SENSOR
IMPORTANT: Do not
HOT
4
use sealent on threads
I
MPORTANT: Do not
1
4
2
(OPTIONAL)
PUTTY
(If required)
MOUNTING
SURFACE
TIGHTEN
SPIN NUTS
I
MPORTANT: Do not
use sealant on threads
10
2
5
COLD

Advertisement

loading