Deflection Yoke Neck Rotation Adjustment - Sony TRINITRON PVM-1953MD Service Manual

Color video monitor
Hide thumbs Also See for TRINITRON PVM-1953MD:
Table of Contents

Advertisement

5. For VMC, use the 6-pole magnet to adjust the R and B dots to
The VMC adjustment does
not change the opening of
the 6-pole magnet, but turns
it left and right.
be symmetrical above and below the G dot. (*2)
*2:
6-pole magnet
24 Adjust so that the displacement
up and down are the same.
6. Adjust by repeating the adjustments in Items 2 through 5. (*3)
*3.: The above adjustment may affect the landing, so after
this adjustment, check the landing again.
7. After the adjustment is complete, paint on the knobs to lock
them.
V. STAT magnet
BMC magnet
|
3-6. DEFLECTION YOKE NECK ROTATION
ADJUSTMENT
If there is misconvergence at both sides on the X or Y axis of the
screen, turn the neck of the deflection yoke in the direction of the
arrow to reduce the misconvergence for the entire CRT screen to
within the tolerance.
1.
Reverse misconvergence pattern
Tum the deflection yoke neck down.
Positive misconvergence pattern
Turn the deflection yoke neck up.
L
L
As viewed from the CRT
BA
screen, tur the deflection
yoke neck to the right.
BR
Fe) w
Pattern when deflection yoke too far to the right
2. Insert the three wedges in the deflection yoke and CRT funnel
surface to fasten the deflection yoke.
14" Wedge positions
20" Wedge positions