Section 10: Setting Torque Limit Valves
April 2013
10.2
Closing Torque
Using the handwheel, close the valve completely while observing the Torque Dial rotation for a
reference operating point.
Figure 7
Refer to the EIM Job Specification Sheet for additional suggested setpoints. Determine
appropriate setpoint and press down on the TSC dial indicator approximately 1/16" with a flat
blade screwdriver and position the arrow for the desired setting. Release to secure in place.
Partially open the valve and reseat with the Handwheel to ensure the set point is accurate.
18
Set Closing Value
Installation, Operation and Maintenance Manual
Part Number: E7K-400-0913
Setting Torque Limit Valves