Setup

  1. Power up. Insert 2-AA batteries into the sensor, then into the clock. Observe the correct polarity.
    Setup
  2. Configure basic settings. Hold the SET button for 3 seconds to enter settings menu. Use the +/- buttons to adjust and SET to confirm.
    Setting order:
    1. Language: English | Español

      Note: When Español is selected, weekday and sub menu instructions will be in Spanish. Calendar order: Day, Month, Year.
    2. Beep ON | OFF
    3. Atomic ON | OFF

      Note: When the Atomic setting is set to OFF, the menu will skip to item 6, your Hour setting.
    4. DST ON | OFF (Daylight Saving Time)
    5. Time Zone

      AST Atlantic
      EST Eastern
      CST Central
      MST Mountain
      PST Pacific
      AKT Alaskan
      HAT Hawaiian
    6. Hour
    7. Minutes
    8. Year
    9. Month
    10. Date
    11. Fahrenheit | Celsius

Note: When setting the hour, AM indicates times before 12:00 (noon) and PM indicates time after 12:00 (noon).

  1. Place outdoor sensor outside in the shaded location and enjoy your weather information.

Atomic Time

  • The station will automatically search for the atomic time signal at UTC 7:00, 8:00, 9:00, 10:00, and 11:00.
  • Press and release the SET button to search manually for atomic time signal.
  • Press the SET button to select daylight saving time ON/OFF. If you do not observe DST, use the +/- button to turn off the Daylight Saving Time Indicator.
  • For information about WWVB visit: http://bit.ly/AtomicTime

Display icons

Display icons overview

Low Battery
Atomic Time
Trend Arrow
AM | PM
Fahrenheit | Celsius
Sensor Signal Strength
Alarm | Snooze

Time Alarm

  • Set: Hold the ALARM button for 3 seconds to enter alarm settings.
  • Use the +/- buttons to adjust and ALARM to confirm.

Time Alarm
Deactivate | Activate: The alarm is active when set.
Press and release the ALARM button to deactivate or activate the alarm. The clock icon will show when alarm is active.

Snooze: Press and release the SNOOZE button to silence the alarm for 10 minutes. Snooze can be repeated.

Moon Phase

The moon phase is based on the lunar calendar and the Year, Month, and Date settings set within this clock. Most Internet moon phase calculations are based on the lunar calendar and can be categorized into one of the following

New Moon
Small Waxing Crescent
Large Waxing Crescent
First Quarter
Small Waxing Gibbous
Large Waxing Gibbous
Full Moon
Large Waning Gibbous
Small Waning Gibbous
Last Quarter
Large Waning Crescent
Small Waning Crescent

HI | LO Temperature

  • Press the PLUS button to view HI Temperature.
  • Press again to view LO Temperature.
  • Hold the PLUS button for 5 seconds to reset HI and LO temperature.
    HI / LO TemperatureNote: All records reset at midnight.

Temperature Trend Arrows

The outdoor temperature trend indicators update every 15 minutes and provide a 1 hour comparison of readings that took place every 15 minutes within that hour.
The temperature will have to rise or fall by 2°F (1°C) or more within the hour for the arrows to change.


Temperature rose

Temperature is unchanged

Temperature fell

Sensor Reception

  • Hold the - button 3 seconds to search for the sensor.
  • The strength signal icon will flash until the sensor signal is received or for 3 minutes if no signal available.
  • The signal will show solid when connected to the sensor.

Low Battery Icon

  • Battery icon by time-Change batteries in the clock.
  • Battery icon by outdoor temperature-Change batteries in the sensor.

Mount Temperature Sensor

  • Mount the outdoor sensor on a north-facing wall or in any well-shaded area. Under an eave or deck rail is preferred.
  • The maximum wireless transmission range to the forecast station is over 300 feet (91 meters) in open air; this does not include barriers such as walls or floors.
  • Be sure the outdoor sensor is mounted vertically.


This product can expose you to chemicals including styrene, which is known to the State of California to cause cancer. For more information go to: www.P65Warnings.ca.gov

Position Clock

The clock has a pullout stand to sit on a desk or table, or openings on the back to mount on a wall.

  • For best Atomic time reception orientate the clock with the front or the back facing Ft. Collins, Colorado.
  • Choose a location 6 feet or more from electronics such as cordless phones, gaming systems, televisions, microwaves, routers etc.
  • Place within range of the outdoor sensor (330 feet open air).

Restart

When the outdoor readings show dashes:

  • Bring the sensor in the house five feet from the station.
  • Remove batteries from the sensor, and the batteries from the clock.
  • Press any button 20 times.
  • After 15 minutes insert batteries into the sensor, and into the clock.
  • Wait 15 minutes to establish a strong connection.
  • Place sensor outside in shaded location.

Specifications

Indoor Temperature Range: 32°F to 122°F (0°C to 50°C)
Outdoor Temperature Range: -40°F to 140°F (-40°C to 60°C)
Transmission Range: Over 300 ft. (91 meters) RF 433MHz (open air)
Power Requirements: 513-1417CH - 2 AA batteries (not included)
TX141-Bv3 - 2 AA batteries (not included)
Battery Life: 513-1417CH-over 12 months
TX141-Bv3-over 12 months
Dimensions: 513-1417CH- 11.10" W x 1.14" D x 6.75" H
(28.19 W x 2.89 D x 17.15 H cm)
TX141-Bv3- 1.57" L x 0.79" W x 5.12" H
(3.98 L x 2.0 W x 13.0 H cm)

Care and Maintenance

  • Do not mix old and new batteries
  • Do not mix Alkaline, Standard, Lithium or Rechargeable Batteries
  • Always purchase the correct size and grade of battery most suitable for intended use.
  • Replace all batteries of a set at the same time.
  • Clean the battery contacts and also those of the device prior to battery installation.
  • Ensure the batteries are installed with correct polarity (+ and -).
  • Remove batteries from equipment which is not to be used for an extended period.
  • Promptly remove expired batteries.

Help Us, Help You!
If you have ideas for features or support solutions you'd like to see us make, please let us know! We truly want to make owning a La Crosse Technology product not only a practical experience, but also a fun one. So email us at: store@lacrossetechnology.com

Let's Be Social!
Follow us on our social media outlets for the latest promotions, product support, and awesome giveaways.

For online video support: http://bit.ly/LaxTechTalk
www.lacrossetechnology.com/support

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download La Crosse Technology 513-1417CH - Atomic Digital Wall Clock with Temperature and Moon Phase Manual

Advertisement

Need Assistance?

Do you have a question about the 513-1417CH that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents