GE JVM1660CB002 Installation Instructions Manual page 17

Hide thumbs Also See for JVM1660CB002:
Table of Contents

Advertisement

Available languages

Available languages

Installation Instructions
B5.| ADAPTING MICROWAVE
BLOWER FOR OUTSIDE
BACK EXHAUST (cont.)
Rotate blower unit counterclockwise
180°.
Before Rotation
After Rotation
ack of
Microwave
Microwave
4 | Gently remove the wires from the grooves.
Reroute the wires through grooves on other side
of the blower unit.
Before Rerouting
After Rerouting
Wires Routed Through Right Side
Wires Routed Through Left Side
Roll the blower unit 90° so that fan blade
openings are facing out the back of the
microwave.
Before Rolling
After Rolling
"0
Back of
Microwave
Microwave
17
| 6 | Place the blower unit back into the opening.
AFTER: Fan Blade
Openings Facing Back
CAUTION:
Do not pull or stretch the blower
unit wiring. Make sure the wires are not
pinched.
NOTE: The blower unit exhaust
openings should match exhaust
openings on rear of microwave oven.
Secure the blower unit to the microwave with
the screw from Step 1.
F
Blower Plate
Back of
Microwave
Blower Motor
Screw
Replace the blower plate in the same position
as before with the screw.
9 | Attach the exhaust adaptor to the rear of the
oven by sliding it into the guides at the top
center of the back of the oven.
Adaptor
Back of
Microwave
Locking Tabs
Push in securely until it is in the lower locking
tabs. Take care to assure that the damper hinge
is installed so that it is at the top and that the
damper swings freely.