DISASSEMBLY- AND RE-ASSEMBLY ADVISE
- To open the apliance,
First remove the filter cover
(item 24) then remove the
vario knob button (item 11)
with a screwdriver as shown
in the picture.
- To remove the button panel (item 13), first loosen
mounting screws (A), now by using a screwdriver unlock
the 4 snap connection and separate the panel from the
housing. (see picture)
- Display cover (item 12) now can easely be removed from
the button panel.)
- To remove the motor, you need a torx screwdriver with a
14.5cm long shank. Screwdriver 9965 000 08332 can be
used.

ELECTRICAL DIAGRAM

MOTOR
POWER
MODULE
CORD WINDER
Brown
Blue
Black
M
Black/White

REPAIR INSTRUCTION

- Cotton dustbags, are used in countries in which paper
dustbags are not available.
- If the reel half spring unit is replaced, shaft
lubricated with silicone grease. Do not apply any silicone
grease to or spill any grease on terminals (39) or conductors
(38).
- Item 37 is provided with a long cord-winder spring, but
both long and short cords can be used in combination with
this spring. (L = 9.3 m)
- Depending on the original cord, the spare cord must be
shortened to the length of the original cord.
- The cord winder spring must be tensioned to the maximum
level and then be rewound approx. 1.5 turn
- Item 10, air valve, opens to cool the motor if the air
displacement is too low or if the airflow is blocked.
- To adjust the telescopic tube (item 46) to the required
length, push the adjustment collar in the direction of the
arrow while sliding the top section of the telescopic tube
into or out of the lower section.
- If the function of the electronic control unit (item 15) is
not required, the Triac must be short-circuited in the
manner shown in the circuit diagram.
- When the vacuum cleaner is used to suck up fine dust the
pores of the dustbag may become clogged, causing the
passage of air through the dustbag to become obstructed.
As a result, the dustbag-full indicator will indicate that the
dustbag needs to be replaced, eventhough the dustbag is not
full at all.
Triac