Mitsubishi Electric MUZ-HA VF Series Service Manual page 6

Table of Contents

Advertisement

Indoor model
Power supply
Power input *1
Running current
*1
Model
Current *1
Dimensions W × H × D
Weight
Air direction
Super High
High
Med.
Low
Super High
High
Med.
Low
Super High
High
Med.
Low
Super High
High
Med.
Low
Super High
High
Med.
Low
Super High
High
Med.
Low
Fan speed regulator
Remote controller model
NOTE : Test conditions are based on ISO 5151.
Cooling : Indoor
Outdoor Dry-bulb temperature 35°C
Heating : Indoor
Outdoor Dry-bulb temperature 7°C
*1 Measured under rated operating frequency.
Specifications and rated conditions of main electric parts
Fuse
Horizontal vane motor
Varistor
Terminal block
OBH822H
Cooling
W
Heating
Cooling
A
Heating
Cooling
A
Heating
mm
kg
m
/h
3
m
/h
3
dB(A)
dB(A)
rpm
rpm
Dry-bulb temperature 27°C
Dry-bulb temperature 20°C
(F11)
T3.15AL250V
(MV)
12 V DC
(NR11)
470V
(TB)
3P
MSZ-HR60VF
MSZ-HR60VFK
Single phase 230 V, 50 Hz
55
55
0.50
0.50
RC0J40-SA
0.50
0.50
923 × 305 × 262
12.5
5
1,176
924
756
624
1,176
1,002
786
642
50
44
38
33
50
44
38
33
1,220
1,000
850
730
1,220
1,070
880
750
4
RH18A
Wet-bulb temperature
Wet-bulb temperature
6
MSZ-HR71VF
MSZ-HR71VFK
Single phase 230 V, 50 Hz
55
55
0.50
0.50
RC0J40-SA
0.50
0.50
923 × 305 × 262
12.5
5
1,176
924
756
624
1,176
1,002
786
642
50
44
38
33
50
44
38
33
1,220
1,000
850
730
1,220
1,070
880
750
4
RH18A
19°C
6°C

Hide quick links: