REPLACING THE AGITATOR ASSEMBLY
1 When to replace the agitator assembly
The agitator assembly should be replaced when the brushes
are worn
Brushes should be checked by holding a card
across the lower plate (see illustration)
If the bristles on
the agitator assembly do not touch the card, you should
replace the agitator assembly for best cleaning results
How to replace the agitator assembly
Place the vacuum cleaner handle in the upright position
(See the Handle Adjustments section ) Remove the lower
plate as outlined in the Removing/Installing the Lower Plate section
After the lower plate Is
removed, carefully lift up the agitator assembly until it clears both sides of the nozzle
housing
While holding the agitator assembly up, remove the belt
CAUTION
The two end caps may come off along with the two washers as you lift the
agitator assembly out
Do not lose the two small washers
Look at the exploded view of
the agitator assembly below for correct assembly of the parts
3 To replace the agitator assembly
Place the belt over the belt pulley on the agitator unit
(NOTE
There is a place for the belt
to fit on one end of the agitator assembly only) Replace both washers and end caps (see
illustration below for correct assembly)
After assembling the belt, washers and end caps,
place the agitator assembly back into the nozzle housing by aligning each end cap
After completing the assembly, rotate the brush, turning it by hand to assure that
it rotates smoothly and the part is assembled correctly
Replace the lower plate as outlined in the Removing/Installing the Lower Plate section