CONSUMER: READ AND SAVE THESE INSTRUCTIONS
Locating Your Serial Number:
Your serial number can be found on a white label on the right side cover of your heater. For Example:
150812779. Have your Serial Number ready before calling customer service at 800-641-6996.
DANGER
to comply with the instructions and warnings provided with this heater. Failure to comply
can result in fire or explosion that can cause property loss, bodily injury, or loss of life. Only
persons who can follow and understand these instructions should operate or service this
heater. If you need heater info; such as an operating manual, labels, etcetera, contact Pinnacle
Climate Technologies at 800-641-6996.
DANGER
IN WELL-VENTILATED AREAS. INDOOR USE PERMITTED ONLY FOR: THE TEMPORARY
HEATING OF ADEQUATELY VENTILATED BUILDINGS OR STRUCTURES UNDER
CONSTRUCTION, ALTERATION OR REPAIR. This is an unvented portable heater that uses air
(Oxygen) from within the area in which it is used. Failure to provide adequate combustion and
ventilation air will result in asphyxiation, carbon monoxide poisoning, bodily injury or death.
Refer to "Ventilation" on Page 6.
WARNING: PERSONS WHO ARE IMPAIRED OR UNDER THE INFLUENCE
OF ALCOHOL OR DRUGS SHOULD NOT OPERATE HEATER.
FACTORY ID: 500
Master is a registered trademark of Pinnacle Climate Technologies, Inc.
MODEL NUMBERS:
140TMHD-KFA / 190TMHD-KFA / 215TMHD-KFA
GENERAL HAZARD WARNING: READ AND UNDERSTAND
ALL OF THE INSTRUCTIONS IN THIS MANUAL BEFORE
ASSEMBLING, STARTING, OR SERVICING THE HEATER. Be sure
NOT FOR USE IN RESIDENTIAL LIVING AREAS OR IN ENCLOSED
SPACES WITHOUT ADEQUATE VENTILATION. THIS HEATER
IS SUITABLE FOR OUTDOOR USE, AND INDOOR USE ONLY
Fax: 320-251-2922 • Web: www.masterindustrialproducts.com • Email: info@pinnacleclimate.com
KEROSENE FORCED
AIR HEATER
User's Manual &
Operating Instructions
Sauk Rapids, MN 56379 USA • Toll Free (800) 641-6996
© 2023 Pinnacle Climate Technologies, Inc. MAKB-440

Advertisement

Table of Contents
loading

Summary of Contents for Master 140TMHD-KFA

  • Page 1 OF ALCOHOL OR DRUGS SHOULD NOT OPERATE HEATER. FACTORY ID: 500 Sauk Rapids, MN 56379 USA • Toll Free (800) 641-6996 Fax: 320-251-2922 • Web: www.masterindustrialproducts.com • Email: info@pinnacleclimate.com Master is a registered trademark of Pinnacle Climate Technologies, Inc. © 2023 Pinnacle Climate Technologies, Inc. MAKB-440...
  • Page 2: Table Of Contents

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE TABLE OF CONTENTS Safety Information............2-3 Maintenance..............8-9 What’s in the Box.............4 Wiring Diagrams............10 Troubleshooting Guide..........11 Specifications..............5 Features................5 Exploded View..............12 Assembly Instructions............5 Parts List................13 Operation..............6-7 Limited Warranty.............14 SAFETY INFORMATION FIRE, BURN, INHALATION AND EXPLOSION HAZARD.
  • Page 3: Safety Information

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE SAFETY INFORMATION (CONT.) RISK OF INDOOR WARNING RISK OF ELECTRIC WARNING AIR POLLUTION! SHOCK! The products described in this manual are ALWAYS use only the electrical power (voltage and frequency) specified on the model plate of the heater.
  • Page 4: What's In The Box

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE WHAT’S IN THE BOX Tools Needed: Tip: Be sure to remove the axle from the side of the - Phillips Head Screw Driver Styrofoam packaging. - 8 mm open end wrench Tip: Use a power screwdriver and locking wrench - 19 mm open end wrench for easier assembly.
  • Page 5: Specifications

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE SPECIFICATIONS Model # 140TMHD-KFA 190TMHD-KFA 215TMHD-KFA Rating: Btu/Hr / kW 140,000 / 41 190,000 / 55.68 215,000 / 63.01 Fuel Consumption: Gal/Hr / L/Hr 1.1 / 4.16 1.42 / 5.38...
  • Page 6: Operation

    FILL THE TANK OUTDOORS. BE SURE THAT if more heaters are being used. THE HEATER IS ON LEVEL GROUND WHEN FUELING, AND NEVER OVERFILL THE TANK. Minimum Ventilation Opening Needed 140TMHD-KFA DO NOT USE GAS- WARNING OLINE OR CRANK- 4.2 ft.² CASE DRAININGS.
  • Page 7 (grounded) extension cord that is at least Model Number Pump Pressure 6 feet long and is a minimum of 14 AWG rating. 140TMHD-KFA 6.6 PSI (0.46 BAR) 4. Turn thermostat control knob to desired 190TMHD-KFA 8.5 PSI (0.59 BAR) temperature setting.
  • Page 8: Maintenance

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE MAINTENANCE Service: ROTOR: DO NOT TAMPER WITH THE UNIT. HAVE The rotor with carbon vanes should be evaluated every heating season. The rotor is behind the air A COMPETENT SERVICEMAN MAKE ANY filters.
  • Page 9 After removing the spark plug, follows: clean the terminals with a wire brush. Re-gap the Model Number Pump Pressure terminals to 0.140” (3.5mm). See Figure 5. 140TMHD-KFA 6.6 PSI (0.46 BAR) Spark Plug 190TMHD-KFA 8.5 PSI (0.59 BAR) Burner Head 215TMHD-KFA 9.0 PSI (0.62 BAR)
  • Page 10: Wiring Diagrams

    WHILE CONNECTED TO A POWER SOURCE WIRING DIAGRAMS 140TMHD – 215TMHD-KFA 140TMHD-KFA / 190TMHD-KFA 215TMHD-KFA (140TMHD-KFA) (190TMHD-KFA / 215TMHD-KFA) Note: Models 140TMHD-KFA / 190TMHD-KFA / 215TMHD-KFA have a digital display. © 2023 Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual...
  • Page 11: Troubleshooting Guide

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE TROUBLESHOOTING GUIDE Problem Possible Cause Solution Heater Ignites, but main PCB Incorrect pump pressure. Adjust pump pressure. shuts off after a short period 2. Dirty input, output or lint filter. 2.
  • Page 12: Exploded View

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE EXPLODED VIEW © 2023 Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual...
  • Page 13: Parts List

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE PARTS LIST Description 140TMHD-KFA 190TMHD-KFA 215TMHD-KFA Drain Bolt 70-002-0115 70-002-0115 70-002-0115 Fuel Gauge 70-007-0215 70-007-0215 70-007-0215 Fuel Filter 70-003-0200 70-003-0200 70-003-0200 Fuel Cap - Large Plastic 70-006-0140...
  • Page 14: Limited Warranty

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE LIMITED WARRANTY Pinnacle Climate Technologies, Inc. warrants this product If Pinnacle Climate Technologies, Inc. finds the item to to the original retail purchaser only, to be free from defects be in normal operating condition, or not defective the item in material and workmanship for a period of one (1) year will be returned freight collect.

This manual is also suitable for:

190tmhd-kfa215tmhd-kfa

Table of Contents