5-3.
Circuit Breakers And Fuses
4
Turn
Off
welding
power
source,
disconnect
input
power, and check
voltage
on
input capacitors according
to
Section
5-2
before
proceeding.
1
Circuit Breaker CB1
If
CB1
opens,
remote
devices
using
115 volts
from Remote
14
receptacle stop. Manually
reset
CB1.
2
Circuit Breaker CB2
If
CB2
opens,
remote
devices
using
24 volts from Remote 14
receptacle stop. Manually
reset
CB2.
3
Circuit Breaker CB3
If CB3 opens, devices connected
to the 115 volt
twistlock
receptacle
stop.
Manually
reset
CB3.
4
Fuse Fl
If Fl opens, the
welding
power
source
shuts down.
5
Fuse F3
6
Fuse F4
If F3
or
F4 opens,
remote control
devices connected
to
Remote 17
receptacle
RC1 may shut down.
See Parts List for fuse
ratings.